Multiplex Assay Kit for Podocalyxin (PODXL) ,etc. by FLIA (Flow Luminescence Immunoassay)
Gp200; PCLP; PC; PCX; Podocalyxin Like Protein 1; GCTM-2 antigen
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA768Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample Typetissue homogenates, cell lysates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.1-100ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.033 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 427
US$ 443
US$ 468
US$ 501
US$ 534
US$ 583
US$ 657
Result
For more details, please contact local distributors! US$ 821 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Podocalyxin (PODXL) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Podocalyxin (PODXL) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Podocalyxin (PODXL) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Podocalyxin (PODXL) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 82-96 | 89 |
EDTA plasma(n=5) | 85-103 | 99 |
heparin plasma(n=5) | 79-97 | 93 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Podocalyxin (PODXL) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Podocalyxin (PODXL) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Podocalyxin (PODXL) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 86-101% | 99-105% | 84-98% | 89-96% |
EDTA plasma(n=5) | 98-105% | 80-103% | 85-99% | 92-101% |
heparin plasma(n=5) | 98-105% | 92-101% | 80-104% | 95-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:PODXL) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Egypt J Rheumatology and Clinical Immunology | Urinary Podocalyxin and Lupus Nephritis Disease Activity 4473_583473a89b4f569662891fe3df447e45 |
OncoTargets and Therapy | Measurement of serum PODXL concentration for detection of pancreatic cancer Pubmed:29588598 |
Menoufia Medical Journal | Urinary podocalyxin and cyclophilin A: markers for early detection of type 2 diabetic nephropathy |
European Journal of Obstetrics & Gynecology and Reproductive Biology | The Role of Serum Podocalyxin Levels in Recurrent Pregnancy Loss 33765479 |
Life Sciences | Vildagliptin alleviates liver fibrosis in NASH diabetic rats via modulation of insulin resistance, oxidative stress, and inflammatory cascades Pubmed:35671811 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPA768Ra02 | Recombinant Podocalyxin (PODXL) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPA768Ra01 | Recombinant Podocalyxin (PODXL) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA768Ra02 | Polyclonal Antibody to Podocalyxin (PODXL) | WB; IHC; ICC; IP. |
PAA768Ra01 | Polyclonal Antibody to Podocalyxin (PODXL) | WB; IHC; ICC; IP. |
MAA768Ra21 | Monoclonal Antibody to Podocalyxin (PODXL) | WB; IHC; ICC; IP. |
SEA768Ra | ELISA Kit for Podocalyxin (PODXL) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA768Ra | Multiplex Assay Kit for Podocalyxin (PODXL) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |