Multiplex Assay Kit for Podocalyxin (PODXL) ,etc. by FLIA (Flow Luminescence Immunoassay)
Gp200; PCLP; PC; PCX; Podocalyxin Like Protein 1; GCTM-2 antigen
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA768Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeUrine, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.01-10ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.003 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 393
US$ 408
US$ 431
US$ 461
US$ 491
US$ 537
US$ 605
Result
For more details, please contact local distributors! US$ 756 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Podocalyxin (PODXL) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Podocalyxin (PODXL) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Podocalyxin (PODXL) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Podocalyxin (PODXL) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:PODXL) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Egypt J Rheumatology and Clinical Immunology | Urinary Podocalyxin and Lupus Nephritis Disease Activity 4473_583473a89b4f569662891fe3df447e45 |
OncoTargets and Therapy | Measurement of serum PODXL concentration for detection of pancreatic cancer Pubmed:29588598 |
Menoufia Medical Journal | Urinary podocalyxin and cyclophilin A: markers for early detection of type 2 diabetic nephropathy |
European Journal of Obstetrics & Gynecology and Reproductive Biology | The Role of Serum Podocalyxin Levels in Recurrent Pregnancy Loss 33765479 |
Life Sciences | Vildagliptin alleviates liver fibrosis in NASH diabetic rats via modulation of insulin resistance, oxidative stress, and inflammatory cascades Pubmed:35671811 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPA768Hu01 | Recombinant Podocalyxin (PODXL) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPA768Hu02 | Recombinant Podocalyxin (PODXL) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA768Hu02 | Polyclonal Antibody to Podocalyxin (PODXL) | WB; IHC; ICC; IP. |
PAA768Hu01 | Polyclonal Antibody to Podocalyxin (PODXL) | WB; IHC; ICC; IP. |
LAA768Hu71 | Biotin-Linked Polyclonal Antibody to Podocalyxin (PODXL) | WB; IHC; ICC. |
MAA768Hu22 | Monoclonal Antibody to Podocalyxin (PODXL) | WB; IHC; ICC; IP. |
SEA768Hu | ELISA Kit for Podocalyxin (PODXL) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA768Hu | Multiplex Assay Kit for Podocalyxin (PODXL) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
PSA768Hu01 | Antibody Pair for Podocalyxin (PODXL) | ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays. |
KSA768Hu01 | ELISA Kit DIY Materials for Podocalyxin (PODXL) | Main materials for "Do It (ELISA Kit) Yourself". |