Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Prealbumin (PALB) ,etc. by FLIA (Flow Luminescence Immunoassay)
TBPA; PA; PLB; ATTR; TTR; Transthyretin; Prealbumin Amyloidosis Type I; Transports Thyroxine and Retinol
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA726Rb
- Organism SpeciesOryctolagus cuniculus (Rabbit) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.2-200ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.067 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 450
US$ 468
US$ 494
US$ 528
US$ 563
US$ 615
US$ 693
Result
For more details, please contact local distributors! US$ 866 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Prealbumin (PALB) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Prealbumin (PALB) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Prealbumin (PALB) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Prealbumin (PALB) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 83-94 | 91 |
EDTA plasma(n=5) | 96-104 | 101 |
heparin plasma(n=5) | 81-92 | 85 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Prealbumin (PALB) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Prealbumin (PALB) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Prealbumin (PALB) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 93-101% | 93-101% | 91-98% | 80-89% |
EDTA plasma(n=5) | 80-93% | 91-104% | 95-105% | 80-101% |
heparin plasma(n=5) | 82-96% | 80-99% | 83-101% | 97-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:PALB) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Chinese Medical Journal | Screening disease-associated proteins from sera of patients with rheumatoid arthritis: a comparative proteomic study PubMed: 20367977 |
Journal of Vascular Surgery | Circulation levels of acute phase proteins in patients with Takayasu arteritis PubMed: 20100644 |
Journal of Pharmaceutical and Biomedical Analysis | Effect of high dose thiamine on the levels of urinary protein biomarkers in diabetes mellitus type 2 PubMed: 21130593 |
Toxicology Letters | Serum proteomic analysis reveals potential serum biomarkers for occupational medicamentosa-like dermatitis caused by trichloroethylene Pubmed:24960064 |
Journal of Neurochemistry | Schwann cells contribute to neurodegeneration in transthyretin amyloidosis Pubmed:25693163 |
Anal Biochem | Surface plasmon resonance assay of inhibition by pharmaceuticals for thyroxine hormone binging to transport proteins PubMed: 26384643 |
United States Patent Application | Compositions and Methods for Diagnosing Lung Cancer y2016:0077095.html |
Neurotherapeutics | iTRAQ-Based Quantitative Proteomics Reveals the New Evidence Base for Traumatic Brain Injury Treated with Targeted Temperature Management pubmed:29247448 |
Neuroimmunomodulation | CD4+ T Cells Affect the Thyroid Hormone Transport at the Choroid Plexus in Mice Raised in Enriched Environment Pubmed: 30703773 |
Diagnostics | Systemic Alterations of Immune Response-Related Proteins during Glaucoma Development in the Murine Model DBA/2J Pubmed: 32585848 |
Circulation-Genomic and Precision Medicine | Primary Cardiac Involvement in the Rare Transthyretin Ile73Val Mutation: A Case Series Pubmed: 32393063 |
Catalog No. | Related products for research use of Oryctolagus cuniculus (Rabbit) Organism species | Applications (RESEARCH USE ONLY!) |
RPA726Rb01 | Recombinant Prealbumin (PALB) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA726Rb51 | Polyclonal Antibody to Prealbumin (PALB) | WB; IHC; ICC; IP. |
SEA726Rb | ELISA Kit for Prealbumin (PALB) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA726Rb | Multiplex Assay Kit for Prealbumin (PALB) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSA726Rb01 | ELISA Kit DIY Materials for Prealbumin (PALB) | Main materials for "Do It (ELISA Kit) Yourself". |