Multiplex Assay Kit for Aquaporin 4 (AQP4) ,etc. by FLIA (Flow Luminescence Immunoassay)

HMIWC2; MIWC; WCH4; Mercurial-insensitive water channel

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Aquaporin 4 (AQP4) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Aquaporin 4 (AQP4) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Aquaporin 4 (AQP4) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Aquaporin 4 (AQP4) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 94-101 97
EDTA plasma(n=5) 95-102 98
heparin plasma(n=5) 80-95 87

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Aquaporin 4 (AQP4) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Aquaporin 4 (AQP4) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Aquaporin 4 (AQP4) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 82-98% 83-96% 87-95% 89-99%
EDTA plasma(n=5) 78-96% 87-102% 99-105% 85-103%
heparin plasma(n=5) 88-95% 88-99% 89-102% 82-99%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:AQP4) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Neuroscience Letters Aquaporins AQP1 and AQP4 in the cerebrospinal fluid of bacterial meningitis patients ScienceDirect: S0304394011012341
Neurology Astrocytic damage is far more severe than demyelination in NMO Neurology: 208
Fluids and Barriers of the CNS Aquaporin-4 expression in the cerebrospinal fluid in congenital human hydrocephalus PubMed: PMC3651869
Neuropeptides Melanocortin MC4 receptor agonists alleviate brain damage in abdominal compartment syndrome in the rat PubMed: 25616531
Human & Experimental Toxicology Novel effect of Daflon and low-dose γ-radiation in modulation of thioacetamide-induced hepatic encephalopathy in male albino rats Pubmed:26987350
Cephalalgia Decreased levels of aquaporin-4 in the cerebrospinal fluid of patients with idiopathic intracranial hypertension Pubmed:26853804
PLoS One Cerebrospinal fluid biomarkers of infantile congenital hydrocephalus. pubmed:28212403
Journal of Neurotrauma Neuron-derived Plasma Exosome Proteins after Remote Traumatic Brain Injury Pubmed: 31441374
Basic and Clinical Neuroscience Paeonol Protects Against Intrastriatal 6-Hydroxydopamine Rat Model of Parkinson's Disease 33995926
PLoS One Evaluation of aquaporins in the cerebrospinal fluid in patients with idiopathic normal pressure hydrocephalus 34597351
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPA582Ra01 Recombinant Aquaporin 4 (AQP4) Positive Control; Immunogen; SDS-PAGE; WB.
PAA582Ra01 Polyclonal Antibody to Aquaporin 4 (AQP4) WB; IHC; ICC; IP.
MAA582Ra21 Monoclonal Antibody to Aquaporin 4 (AQP4) WB; IHC; ICC; IP.
LAA582Ra72 Biotin-Linked Monoclonal Antibody to Aquaporin 4 (AQP4) WB; IHC; ICC.
SEA582Ra ELISA Kit for Aquaporin 4 (AQP4) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA582Ra Multiplex Assay Kit for Aquaporin 4 (AQP4) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
PSA582Ra01 Antibody Pair for Aquaporin 4 (AQP4) ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays.
KSA582Ra01 ELISA Kit DIY Materials for Aquaporin 4 (AQP4) Main materials for "Do It (ELISA Kit) Yourself".