Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for P-Selectin (SELP) ,etc. by FLIA (Flow Luminescence Immunoassay)
CD62P; Selectin, Platelet; PSEL; GMP140; LECAM3; GRMP; GMRP; PADGEM; Leukocyte-endothelial cell adhesion molecule 3; Platelet activation dependent granule-external membrane
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA569Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range4.88-5000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 1.627 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 380
US$ 394
US$ 416
US$ 445
US$ 475
US$ 518
US$ 584
Result
For more details, please contact local distributors! US$ 730 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of P-Selectin (SELP) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between P-Selectin (SELP) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant P-Selectin (SELP) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of P-Selectin (SELP) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 96-105 | 101 |
EDTA plasma(n=5) | 84-101 | 89 |
heparin plasma(n=5) | 93-104 | 101 |
sodium citrate plasma(n=5) | 78-101 | 93 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level P-Selectin (SELP) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level P-Selectin (SELP) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of P-Selectin (SELP) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 96-104% | 84-92% | 91-105% | 95-105% |
EDTA plasma(n=5) | 84-99% | 80-90% | 80-90% | 80-103% |
heparin plasma(n=5) | 89-102% | 85-94% | 85-101% | 85-99% |
sodium citrate plasma(n=5) | 80-97% | 79-97% | 91-99% | 96-104% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:SELP) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Journalof Vascular Research | Effect of Hirulog-Like Peptide on Balloon Catheter Injury-Induced Neointimal Formation in Femoral Arteries of Minipigs and Relationship with Inflammatory Mediators Karger: 000257340 |
Basic Research in Cardiology | Secretome of apoptotic peripheral blood cells (APOSEC) attenuates microvascular obstruction in a porcine closed chest reperfused acute myocardial infarction model: role of platelet aggregation and vasodilation PubMed: 22899170 |
BioMed research international | Endothelial gene expression and molecular changes in response to radiosurgery in in vitro and in vivo models of cerebral arteriovenous malformations Pubmed: 24199192 |
Free Radical Biology and Medicine | Involvement of nitric oxide with activation of Toll-like receptor 4 signaling in mice with dextran sodium sulfate-induced colitis Pubmed:24992835 |
Materials Science and Engineering: C | MRI-compatible Nb–60Ta–2Zr alloy used for vascular stents: Haemocompatibility and its correlation with protein adsorption Pubmed:25063132 |
Blood Coagul Fibrinolysis.? | Chemical sympathectomy attenuates inflammation, glycocalyx shedding and coagulation disorders in rats with acute traumatic coagulopathy. Pubmed:25325345 |
Inflammation.? | Systemic and Flap Inflammatory Response Associates with Thrombosis in Flap Venous Crisis Pubmed:25448261 |
Endocrine | Effects of glucagon-like peptide-1 on advanced glycation endproduct-induced aortic endothelial dysfunction in streptozotocin-induced diabetic rats: possible roles of Rho kinase- and AMP kinase-mediated nuclear factor κB signaling pathways Pubmed:26758998 |
Microbial Pathogenesis | Protective effects of sinomenine against LPS-induced inflammation in piglets. pubmed:28757275 |
Nutrition & Metabolism | L-Carnitine Supplementation Increases Trimethylamine-N-Oxide but not Markers of Atherosclerosis in Healthy Aged Women Pubmed: 30485835 |
Available at SSRN 3335365 | Evaluating the Platelet Activation Related to the Degradation of Biomaterials by Scheme of Molecular Markers |
Ecotoxicology and Environmental Safety | Molecular mechanisms of lead-induced changes of selenium status in mice livers through interacting with selenoprotein P |
Thrombosis Research | Feasibility study of use of rabbit blood to evaluate platelet activation by medical devices Pubmed: 31838449 |
JOURNAL OF CONTROLLED RELEASE | Polycaprolactone vascular graft with epigallocatechin gallate embedded sandwiched layer-by-layer functionalization for enhanced antithrombogenicity and anti … Pubmed: 31982435 |
OXIDATIVE MEDICINE AND CELLULAR LONGEVITY | The Inhibition of P-Selectin Reduced Severe Acute Lung Injury in Immunocompromised Mice Pubmed: 32377309 |
blood advances | The binding of autotaxin to integrins mediates hyperhomocysteinemia-potentiated platelet activation and thrombosis 34559203 |
Vaccine | The effect of ChAdOx1 nCov-19 vaccine on arterial thrombosis development and platelet aggregation in female rats Pubmed:35183388 |
Int J Biol Macromol | The inhibition of TRIM35-mediated TIGAR ubiquitination enhances mitochondrial fusion and alleviates renal ischemia-reperfusion injury Pubmed:35421414 |
Experimental and Therapeutic Medicine | Construction of a rabbit model with vinorelbine administration via peripherally inserted central catheter and dynamic monitoring of changes in phlebitis and thrombosis Pubmed:35126715 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPA569Ra01 | Recombinant P-Selectin (SELP) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA569Ra01 | Polyclonal Antibody to P-Selectin (SELP) | WB; IHC; ICC; IP. |
LAA569Ra71 | Biotin-Linked Polyclonal Antibody to P-Selectin (SELP) | WB; IHC; ICC. |
MAA569Ra21 | Monoclonal Antibody to P-Selectin (SELP) | WB; IHC; ICC; IP. |
SEA569Ra | ELISA Kit for P-Selectin (SELP) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA569Ra | Multiplex Assay Kit for P-Selectin (SELP) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |