Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Complement Component 5a (C5a) ,etc. by FLIA (Flow Luminescence Immunoassay)
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA388Po
- Organism SpeciesSus scrofa; Porcine (Pig) Same name, Different species.
- Sample TypeSerum, plasma and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.01-10ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.003 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 472
US$ 490
US$ 517
US$ 553
US$ 590
US$ 644
US$ 726
Result
For more details, please contact local distributors! US$ 907 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Complement Component 5a (C5a) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Complement Component 5a (C5a) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Complement Component 5a (C5a) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Complement Component 5a (C5a) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 91-101 | 96 |
EDTA plasma(n=5) | 86-99 | 94 |
heparin plasma(n=5) | 96-105 | 99 |
sodium citrate plasma(n=5) | 97-105 | 102 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement Component 5a (C5a) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement Component 5a (C5a) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Complement Component 5a (C5a) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 84-103% | 80-95% | 85-101% | 79-90% |
EDTA plasma(n=5) | 82-105% | 99-105% | 84-99% | 90-98% |
heparin plasma(n=5) | 84-93% | 83-96% | 84-103% | 98-105% |
sodium citrate plasma(n=5) | 82-91% | 96-105% | 89-99% | 99-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:C5a) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Molecular Immunology | Cathepsin D is released after severe tissue trauma in vivo and is capable of generating C5a in vitro ScienceDirect: S0161589011008297 |
Journal of Reproductive Immunology | Elevated complement factor C5a in maternal and umbilical cord plasma in preeclampsia PubMed: 23415845 |
The Journal of Clinical Investigation | Complement component 5 contributes to poor disease outcome in humans and mice with pneumococcal meningitis PubMed: PMC3195471 |
Journal of Antimicrobial Chemotherapy | Efficacy of a synthetic antimicrobial peptidomimetic versus vancomycin in a Staphylococcus epidermidis device-related murine peritonitis model Pubmed: 23645587 |
Journal of Orthopaedic Research | Conversion from external fixator to intramedullary nail causes a second hit and impairs fracture healing in a severe trauma model Pubmed: 23070742 |
SpringerPlus | Therapeutic effects of sesame oil on monosodium urate crystal-induced acute inflammatory response in rats Pubmed: 24353977 |
American Journal fo Reproductive Immunology | Evaluation of the Markers of Inflammation in the Umbilical Cord Blood of Newborns of Mothers with Thrombophilia Pubmed:25209155 |
Gynecol Obstet Invest | Complement Split Products C3a/C5a and Receptors: Are They Regulated by Circulating Angiotensin II Type 1 Receptor Autoantibody in Severe Preeclampsia? PubMed: 26485247 |
Journal of Neuroimmunology | Acute and prolonged complement activation in the central nervous system during herpes simplex encephalitis Pubmed:27235358 |
International Immunopharmacology | Consistency and pathophysiological characterization of a rat polymicrobial sepsis model via the improved cecal ligation and puncture surgery Pubmed:26802602 |
Digital Repository | Dosagem de frações ativadas do sistema complemento em empiema induzido em ratos 10183 |
Environmental Pollution | Cadmium-induced immune abnormality is a key pathogenic event in human and rat models of preeclampsia pubmed:27511439 |
Cancer Letters | Complement C5a/C5aR pathway potentiates the pathogenesis Q5 of gastric cancer by down-regulating p21 expression pubmed:29031586 |
Acta Paediatrica | Serum complement factor 5a levels are associated with nonalcoholic fatty liver disease in obese children DOI: 10.1111/apa.14106 |
Scientific Reports | Splenectomy modulates early immuno-inflammatory responses to trauma-hemorrhage and protects mice against secondary sepsis Pubmed: 30291296 |
Nutrients | The Beneficial Effects of Lactobacillus plantarum PS128 on High-Intensity, Exercise-Induced Oxidative Stress, Inflammation, and Performance in Triathletes Pubmed: 30736479 |
Journal of NeuroVirology | Intrathecal complement activation by the classical pathway in tick-borne encephalitis Pubmed: 30850976 |
PLoS One | Sepsis causes right ventricular myocardial inflammation independent of pulmonary hypertension in a porcine sepsis model Pubmed: 31247004 |
Frontiers in Immunology | C5a/C5aR Pathway is Critical for the Pathogenesis of Psoriasis Pubmed: 31447855 |
Phytomedicine | Novel evidence that an alternative complement cascade pathway is involved in optimal mobilization of hematopoietic stem/progenitor cells in Nlrp3 … |
Aging | C5aR deficiency attenuates the breast cancer development via the p38/p21 axis Pubmed: 32669478 |
STEM CELL REVIEWS AND REPORTS | A Novel Evidence That Mannan Binding Lectin (MBL) Pathway of Complement Cascade Activation is Involved in Homing and Engraftment of Hematopoietic Stem … Pubmed: 32406006 |
Modulation of C5a-C5aR interactions against murine mammary cancer cell line | |
FASEB J | C‐reactive protein inhibits C3a/C3aR‐dependent podocyte autophagy in favor of diabetic kidney disease Pubmed:35503088 |
Catalog No. | Related products for research use of Sus scrofa; Porcine (Pig) Organism species | Applications (RESEARCH USE ONLY!) |
RPA388Po01 | Recombinant Complement Component 5a (C5a) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA388Po01 | Polyclonal Antibody to Complement Component 5a (C5a) | WB; IHC; ICC; IP. |
SEA388Po | ELISA Kit for Complement Component 5a (C5a) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA388Po | Multiplex Assay Kit for Complement Component 5a (C5a) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |