Multiplex Assay Kit for Thyroglobulin (TG) ,etc. by FLIA (Flow Luminescence Immunoassay)

AITD3; TGN

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Thyroglobulin (TG) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Thyroglobulin (TG) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Thyroglobulin (TG) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Thyroglobulin (TG) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 91-101 94
EDTA plasma(n=5) 88-95 92
heparin plasma(n=5) 93-101 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Thyroglobulin (TG) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Thyroglobulin (TG) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Thyroglobulin (TG) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 82-104% 92-99% 80-91% 81-91%
EDTA plasma(n=5) 85-101% 86-94% 95-105% 83-91%
heparin plasma(n=5) 94-103% 94-102% 82-96% 97-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:TG) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Thyroid. Iodine Storage and Metabolism of Mild to Moderate Iodine-Deficient Pregnant Rats. pubmed:28358234
Lipids in Health and Disease Heat shock protein 70 promotes lipogenesis in HepG2 cells Pubmed:29631603
Available at SSRN 3335365  Evaluating the Platelet Activation Related to the Degradation of Biomaterials by Scheme of Molecular Markers
journal of thoracic and cardiovascular surgery Evaluating Platelet Activation Related to the Degradation of Biomaterials Using Molecular Markers Pubmed: 32812629
Marine Drugs The Inhibitory Effect of Protamine on Platelets is Attenuated by Heparin without Inducing Thrombocytopenia in Rodents Pubmed: 31533230
ACS Omega. Purification and Characterization of Novel Collagen Peptides against Platelet Aggregation and Thrombosis from Salmo salar Pubmed: 32832753
Evid Based Complement Alternat Med Effect of Acupoint Embedding on Serum Leptin and Hypothalamus Leptin Receptor Expression in Rats with Simple Obesity 34659432
Antioxidants Antioxidant Effect of Tyr-Ala Extracted from Zein on INS-1 Cells and Type 2 Diabetes High-Fat-Diet-Induced Mice Pubmed:35740008
Journal of Food Science Tripeptide Hyp‐Asp‐Gly from collagen peptides inhibited platelet activation via regulation of PI3K/Akt‐MAPK/ERK1/2 signaling pathway Pubmed:35703476
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA355Hu01 Recombinant Thyroglobulin (TG) Positive Control; Immunogen; SDS-PAGE; WB.
PAA355Hu01 Polyclonal Antibody to Thyroglobulin (TG) WB; IHC; ICC; IP.
LAA355Hu71 Biotin-Linked Polyclonal Antibody to Thyroglobulin (TG) WB; IHC; ICC.
MAA355Hu22 Monoclonal Antibody to Thyroglobulin (TG) WB; IHC; ICC; IP.
SEA355Hu ELISA Kit for Thyroglobulin (TG) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA355Hu CLIA Kit for Thyroglobulin (TG) Chemiluminescent immunoassay for Antigen Detection.
LMA355Hu Multiplex Assay Kit for Thyroglobulin (TG) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.