Multiplex Assay Kit for Carcinoembryonic Antigen (CEA) ,etc. by FLIA (Flow Luminescence Immunoassay)

CD66E; CD66; CEACAM5; Carcinoembryonic Antigen-related Cell Adhesion Molecule 5; Carcinoembryonic Antigen

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Carcinoembryonic Antigen (CEA) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Carcinoembryonic Antigen (CEA) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Carcinoembryonic Antigen (CEA) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Carcinoembryonic Antigen (CEA) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 92-99 96
EDTA plasma(n=5) 80-104 92
heparin plasma(n=5) 92-105 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Carcinoembryonic Antigen (CEA) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Carcinoembryonic Antigen (CEA) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Carcinoembryonic Antigen (CEA) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-97% 81-99% 83-99% 96-104%
EDTA plasma(n=5) 95-105% 80-89% 80-99% 96-103%
heparin plasma(n=5) 91-105% 96-104% 98-105% 87-96%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:CEA) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
BioFactors Ginger ingredients inhibit the development of diethylnitrosoamine induced premalignant phenotype in rat chemical hepatocarcinogenesis model PubMed: 20872761
Life Sciences Comparison of angiotensin converting enzyme inhibitors and angiotensin II type 1 receptor blockade for the prevention of premalignant changes in the liver ScienceDirect: S0024320511002700
Iranian journal of basic medical sciences Saffron Aqueous Extract Inhibits the Chemically-induced Gastric Cancer Progression in the Wistar Albino Rat PubMed: PMC3637902
Biosensors and Bioelectronics Handy, rapid and multiplex detection of tumor markers based on encoded silica-hydrogel hybrid beads array chip Pubmed: 23672876
Asian Pac J Cancer Prev. Association of Paraoxonase-1 (Q192R and L55M) Gene Polymorphisms and Activity with Colorectal Cancer and Effect of Surgical Intervention. Pubmed:25684529
Journal of Analytical Atomic Spectrometry Detection of HIV-1 p24 antigen using streptavidin–biotin and gold nanoparticles based immunoassay by inductively coupled plasma mass spectrometry Rsc:Source
Breast Activated Leukocyte Cell Adhesion Molecule (ALCAM) in Saudi Breast Cancer Patients as Prognostic and Predictive Indicator PubMed: 26446295
The Journal of Toxicological Sciences Gene expression analysis in the lung of the rasH2 transgenic mouse at week 4 prior to induction of malignant tumor formation by urethane and N-methylolacrylamide PubMed: 26558449
PLoS One Collecting Protein Biomarkers in Breath Using Electret Filters: A Preliminary Method on New Technical Model and Human Study Pubmed:26934615
Journal of Applied Pharmaceutical Science Chemopreventive effect of Indigofera linnaei extract against diethylnitrosamine induced hepatocarcinogenesis in rats 2071_pdf.pdf
Analytical chemistry Temporal Sensing Platform Based on Bipolar Electrode for the Ultrasensitive Detection of Cancer Cells pubmed:27506255
Frontiers in Physiology  Anticarcinogenic potential of ethanol extract of Indigofera cordifolia Roth.(Fabales: Fabaceae) on diethylnitrosamine induced hepatocarcinogenesis in rats v04n07a07a
Analytica Chimica Acta Ultrasensitive cathode photoelectrochemical immunoassay based on TiO2 photoanode-enhanced 3D Cu2O nanowire array photocathode and signal amplification by … Pubmed:29866267
Journal of Cancer Evaluation of Detection Methods and Values of Circulating Vascular Endothelial Growth Factor in Lung Cancer Pubmed:29675110
Clinical Breast Cancer 8-Hydroxy-2'-deoxyguanosine as a Discriminatory Biomarker For Early Detection of Breast Cancer
Journal of Ethnopharmacology Preventive potential of dietary inclusion of Brachystegia eurycoma (Harms) seeds on N-methyl-N-nitrosourea-induced colon carcinogenesis in Wistar rats Pubmed: 30953819
Asian Journal of Pharmacy and Pharmacology Chemopreventive effects of on diethylnitrosamine induced and Indigofera cassioides phenobarbital promoted rat liver carcinoma
Biomaterials DNA-templated porous nanoplatform towards programmed “double-hit” cancer therapy via hyperthermia and immunogenicity activation Pubmed: 31374481
Biology Piperine Regulates Nrf-2/Keap-1 Signalling and Exhibits Anticancer Effect in Experimental Colon Carcinogenesis in Wistar Rats Pubmed: 32967203
Oncology Research and Treatment Evaluation of the Diagnostic and Predicative Values of 8-Iso-Prostaglandin F2α as a Biomarker of Breast Cancer Pubmed: 32721979
Journal of Functional Foods Chemopreventive effect of dietary inclusion with Crassocephalum rubens (Juss ex Jacq) leaf on N-methyl-N-nitrosourea (MNU)-induced colorectal carcinogenesis in …
Lateral Flow Immunosensor for Ferritin Based on Dual Signal-Amplified Strategy by Rhodium Nanoparticles
Anti-Cancer Activity of Piperine Against Colon Carcinogenesis Via Modulation of NF-κB/Nrf-2/Keap1/HO-1 Signalling Pathways
Microchemical Journal Magnetic immunoassay for tumor clinical diagnosis based on rolling circular amplification (RCA) coupled with ICP-MS
Anticancer efficacy of β-Sitosterol Loaded Hydroxyapatite-Alginate on Colon Cancer Cell in Vivo
sensors and actuators b-chemical A light-induced self-powered competitive immunosensor for the detection of platelet derived growth factor-BB via an elaborately assembled bioconjugate
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPA150Ra01 Recombinant Carcinoembryonic Antigen (CEA) Positive Control; Immunogen; SDS-PAGE; WB.
PAA150Ra01 Polyclonal Antibody to Carcinoembryonic Antigen (CEA) WB; IHC; ICC; IP.
MAA150Ra21 Monoclonal Antibody to Carcinoembryonic Antigen (CEA) WB; IHC; ICC; IP.
SEA150Ra ELISA Kit for Carcinoembryonic Antigen (CEA) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA150Ra Multiplex Assay Kit for Carcinoembryonic Antigen (CEA) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.