Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Thrombopoietin (TPO) ,etc. by FLIA (Flow Luminescence Immunoassay)
THPO; MGDF; MKCSF; ML; MPLLG; Myeloproliferative Leukemia Virus Oncogene Ligand; Megakaryocyte Growth And Development Factor; Megakaryocyte Stimulating Factor
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA135Ca
- Organism SpeciesCanis familiaris; Canine (Dog) Same name, Different species.
- Sample TypeSerum, plasma and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.98-1000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.327 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 449
US$ 467
US$ 492
US$ 527
US$ 562
US$ 613
US$ 691
Result
For more details, please contact local distributors! US$ 864 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Thrombopoietin (TPO) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Thrombopoietin (TPO) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Thrombopoietin (TPO) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Thrombopoietin (TPO) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 98-105 | 101 |
EDTA plasma(n=5) | 88-99 | 95 |
heparin plasma(n=5) | 93-105 | 99 |
sodium citrate plasma(n=5) | 88-97 | 94 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Thrombopoietin (TPO) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Thrombopoietin (TPO) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Thrombopoietin (TPO) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 89-98% | 99-105% | 96-105% | 90-104% |
EDTA plasma(n=5) | 84-102% | 82-101% | 86-93% | 84-92% |
heparin plasma(n=5) | 94-101% | 84-104% | 78-101% | 83-93% |
sodium citrate plasma(n=5) | 80-90% | 89-98% | 98-105% | 96-103% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:TPO) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
中国药理学通报 | 黄芪和当归的主要活性成分配伍对骨髓抑制小鼠造血功能的影响 |
Vaccine | The effect of ChAdOx1 nCov-19 vaccine on arterial thrombosis development and platelet aggregation in female rats Pubmed:35183388 |
Asian Journal of Transfusion Science | A cross-sectional study on thrombopoietin levels in immune thrombocytopenia and its correlation with platelet count, megakaryocytes, and treatment response |
Catalog No. | Related products for research use of Canis familiaris; Canine (Dog) Organism species | Applications (RESEARCH USE ONLY!) |
RPA135Ca01 | Recombinant Thrombopoietin (TPO) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA135Ca01 | Polyclonal Antibody to Thrombopoietin (TPO) | WB; IHC; ICC; IP. |
MAA135Ca21 | Monoclonal Antibody to Thrombopoietin (TPO) | WB; IHC; ICC; IP. |
SEA135Ca | ELISA Kit for Thrombopoietin (TPO) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA135Ca | Multiplex Assay Kit for Thrombopoietin (TPO) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |