Multiplex Assay Kit for Interleukin 3 (IL3) ,etc. by FLIA (Flow Luminescence Immunoassay)

MCGF; MULTI-CSF; MCSF; M-CSF; Multiple; Multilineage-Colony-Stimulating Factor; Hematopoietic Growth Factor; P-Cell Stimulating Factor; Mast-Cell Growth Factor

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Interleukin 3 (IL3) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Interleukin 3 (IL3) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Interleukin 3 (IL3) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 3 (IL3) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 87-99 94
EDTA plasma(n=5) 88-102 92
heparin plasma(n=5) 80-99 81

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 3 (IL3) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 3 (IL3) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 3 (IL3) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 92-101% 80-89% 83-101% 87-104%
EDTA plasma(n=5) 90-99% 89-96% 92-101% 78-95%
heparin plasma(n=5) 84-102% 79-97% 83-102% 91-99%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:IL3) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Journal of Toxicology and Environmental Health Effects of 900-MHz Microwave Radiation on γ-Ray-Induced Damage to Mouse Hematopoietic System PubMed: 20391130
BioMed Research International. c-Kit-Positive Adipose Tissue-Derived Mesenchymal Stem Cells Promote the Growth and Angiogenesis of Breast Cancer pubmed:28573141
Molecular Medicine Reports Aquaporin‑4 deletion ameliorates enterovirus 71 infection in mice Pubmed: 32582978
Sao Paulo Med J Leydig and Sertoli cell function in individuals with genital ambiguity, 46, XY karyotype, palpable gonads and normal testosterone secretion: a case-control … Pubmed:35137906
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
APA076Hu01 Active Interleukin 3 (IL3) Cell culture; Activity Assays.
EPA076Hu61 Eukaryotic Interleukin 3 (IL3) Positive Control; Immunogen; SDS-PAGE; WB.
RPA076Hu01 Recombinant Interleukin 3 (IL3) Positive Control; Immunogen; SDS-PAGE; WB.
APA076Hu61 Active Interleukin 3 (IL3) Cell culture; Activity Assays.
RPA076Hu02 Recombinant Interleukin 3 (IL3) Positive Control; Immunogen; SDS-PAGE; WB.
PAA076Hu01 Polyclonal Antibody to Interleukin 3 (IL3) WB; IHC; ICC; IP.
MAA076Hu21 Monoclonal Antibody to Interleukin 3 (IL3) WB; IHC; ICC; IP.
MAA076Hu22 Monoclonal Antibody to Interleukin 3 (IL3) WB; IHC; ICC; IP.
MEA076Hu Mini Samples ELISA Kit for Interleukin 3 (IL3) Enzyme-linked immunosorbent assay for Antigen Detection.
SEA076Hu ELISA Kit for Interleukin 3 (IL3) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA076Hu Multiplex Assay Kit for Interleukin 3 (IL3) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
IGA076Hu21 Mouse Knockin Human Interleukin 3 (IL3) Animal Experiments; Positive Control.