Multiplex Assay Kit for Thrombospondin Type I Domain Containing Protein 7A (THSD7A) ,etc. by CBA (Cytometric Bead Array)

Specificity

This assay has high sensitivity and excellent specificity for detection of Thrombospondin Type I Domain Containing Protein 7A (THSD7A) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Thrombospondin Type I Domain Containing Protein 7A (THSD7A) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Thrombospondin Type I Domain Containing Protein 7A (THSD7A) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Thrombospondin Type I Domain Containing Protein 7A (THSD7A) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 85-102 98
EDTA plasma(n=5) 79-95 90
heparin plasma(n=5) 94-101 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Thrombospondin Type I Domain Containing Protein 7A (THSD7A) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Thrombospondin Type I Domain Containing Protein 7A (THSD7A) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Thrombospondin Type I Domain Containing Protein 7A (THSD7A) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 92-101% 91-99% 91-99% 91-101%
EDTA plasma(n=5) 82-101% 79-102% 97-104% 91-98%
heparin plasma(n=5) 92-105% 86-101% 90-98% 97-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
中南大学学报 M 型磷脂酶A2 受体及1 型血小板反应蛋白7A 域在特发膜性肾病中的临床意义
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
SEN909Hu ELISA Kit for Thrombospondin Type I Domain Containing Protein 7A (THSD7A) Enzyme-linked immunosorbent assay for Antigen Detection.
AEN909Hu ELISA Kit for Anti-Thrombospondin Type I Domain Containing Protein 7A Antibody (Anti-THSD7A) Enzyme-linked immunosorbent assay for Antibody Detection.
LMN909Hu Multiplex Assay Kit for Thrombospondin Type I Domain Containing Protein 7A (THSD7A) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMN909Hu Multiplex Assay Kit for Thrombospondin Type I Domain Containing Protein 7A (THSD7A) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.