Multiplex Assay Kit for Sjogren Syndrome Antigen A1 (SSA1) ,etc. by CBA (Cytometric Bead Array)

E3 ubiquitin-protein ligase TRIM21; RO52; RNF81; RO52; TRIM21; 52kDa,Ribonucleoprotein Autoantigen SS-A/Ro; Tripartite Motif-Containing 21; Autoantigen Ro, 52kDa; RING finger protein 81

Specificity

This assay has high sensitivity and excellent specificity for detection of Sjogren Syndrome Antigen A1 (SSA1) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Sjogren Syndrome Antigen A1 (SSA1) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Sjogren Syndrome Antigen A1 (SSA1) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Sjogren Syndrome Antigen A1 (SSA1) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 92-101 95
EDTA plasma(n=5) 85-101 89
heparin plasma(n=5) 81-88 84

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Sjogren Syndrome Antigen A1 (SSA1) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Sjogren Syndrome Antigen A1 (SSA1) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Sjogren Syndrome Antigen A1 (SSA1) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 91-98% 89-101% 80-89% 80-92%
EDTA plasma(n=5) 80-97% 82-93% 83-104% 80-93%
heparin plasma(n=5) 87-101% 95-102% 80-102% 94-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Clinical & Experimental Immunology Activation of Toll‐like receptor 7 signaling in labial salivary glands of primary Sjögren's syndrome patients Pubmed: 30446998
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPD200Hu01 Recombinant Sjogren Syndrome Antigen A1 (SSA1) Positive Control; Immunogen; SDS-PAGE; WB.
PAD200Hu01 Polyclonal Antibody to Sjogren Syndrome Antigen A1 (SSA1) WB; IHC
SED200Hu ELISA Kit for Sjogren Syndrome Antigen A1 (SSA1) Enzyme-linked immunosorbent assay for Antigen Detection.
AED200Hu ELISA Kit for Anti-Sjogren Syndrome Antigen A1 Antibody (Anti-SSA1) Enzyme-linked immunosorbent assay for Antibody Detection.
LMD200Hu Multiplex Assay Kit for Sjogren Syndrome Antigen A1 (SSA1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMD200Hu Multiplex Assay Kit for Sjogren Syndrome Antigen A1 (SSA1) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.