Multiplex Assay Kit for Sequestosome 1 (SQSTM1) ,etc. by CBA (Cytometric Bead Array)

OSIL; PDB3; ZIP3; p62; p62B; p60; A170; Paget Disease Of Bone 3; Oxidative Stress Induced Like; EBI3-associated protein of 60 kDa; Ubiquitin-binding protein p62

Specificity

This assay has high sensitivity and excellent specificity for detection of Sequestosome 1 (SQSTM1) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Sequestosome 1 (SQSTM1) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Sequestosome 1 (SQSTM1) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Sequestosome 1 (SQSTM1) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-92 87
EDTA plasma(n=5) 91-98 95
heparin plasma(n=5) 81-88 84

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Sequestosome 1 (SQSTM1) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Sequestosome 1 (SQSTM1) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Sequestosome 1 (SQSTM1) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 91-101% 90-103% 88-103% 98-105%
EDTA plasma(n=5) 94-103% 99-105% 78-103% 80-96%
heparin plasma(n=5) 86-96% 86-99% 78-92% 80-92%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
BRIEFINGS IN BIOINFORMATICS Lysosome activation in peripheral blood mononuclear cells and prognostic significance of circulating LC3B in COVID-19 33620066
BIOMARKERS OF AUTOPHAGY AND ANTIVIRAL ROLE OF PLACENTA FOR PREDICTING PRETERM DELIVERY IN PATIENTS WITH PRETERM DELIVERY?¡­
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPD198Hu01 Recombinant Sequestosome 1 (SQSTM1) Positive Control; Immunogen; SDS-PAGE; WB.
PAD198Hu01 Polyclonal Antibody to Sequestosome 1 (SQSTM1) WB; IHC; ICC/IF; FCM
MAD198Hu21 Monoclonal Antibody to Sequestosome 1 (SQSTM1) WB; IHC; ICC/IF
MAD198Hu24 Monoclonal Antibody to Sequestosome 1 (SQSTM1) WB; ICC/IF; FCM
MAD198Hu27 Monoclonal Antibody to Sequestosome 1 (SQSTM1) WB
MAD198Hu22 Monoclonal Antibody to Sequestosome 1 (SQSTM1) WB; ICC/IF; FCM
MAD198Hu23 Monoclonal Antibody to Sequestosome 1 (SQSTM1) WB; ICC/IF
MAD198Hu29 Monoclonal Antibody to Sequestosome 1 (SQSTM1) WB
MAD198Hu26 Monoclonal Antibody to Sequestosome 1 (SQSTM1) ICC/IF
MAD198Hu25 Monoclonal Antibody to Sequestosome 1 (SQSTM1) IHC
FAD198Hu08 Anti-Sequestosome 1 (SQSTM1) Monoclonal Antibody FCM
FAD198Hu06 Anti-Sequestosome 1 (SQSTM1) Monoclonal Antibody FCM
FAD198Hu04 Anti-Sequestosome 1 (SQSTM1) Monoclonal Antibody FCM
FAD198Hu02 Anti-Sequestosome 1 (SQSTM1) Monoclonal Antibody FCM
SED198Hu ELISA Kit for Sequestosome 1 (SQSTM1) Enzyme-linked immunosorbent assay for Antigen Detection.
MED198Hu Mini Samples ELISA Kit for Sequestosome 1 (SQSTM1) Enzyme-linked immunosorbent assay for Antigen Detection.
CMD198Hu Multiplex Assay Kit for Sequestosome 1 (SQSTM1) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMD198Hu Multiplex Assay Kit for Sequestosome 1 (SQSTM1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.