Multiplex Assay Kit for Sulfatase Modifying Factor 1 (SUMF1) ,etc. by CBA (Cytometric Bead Array)

FGE; C-alpha-formylglycine-generating enzyme 1

Specificity

This assay has high sensitivity and excellent specificity for detection of Sulfatase Modifying Factor 1 (SUMF1) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Sulfatase Modifying Factor 1 (SUMF1) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Sulfatase Modifying Factor 1 (SUMF1) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Sulfatase Modifying Factor 1 (SUMF1) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-104 86
EDTA plasma(n=5) 79-99 81
heparin plasma(n=5) 79-97 88

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Sulfatase Modifying Factor 1 (SUMF1) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Sulfatase Modifying Factor 1 (SUMF1) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Sulfatase Modifying Factor 1 (SUMF1) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-98% 84-102% 82-101% 78-101%
EDTA plasma(n=5) 79-91% 99-105% 78-99% 84-92%
heparin plasma(n=5) 86-99% 85-99% 96-105% 79-96%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
PLos One Hypoxia Reduces Arylsulfatase B Activity and Silencing Arylsulfatase B Replicates and Mediates the Effects of Hypoxia Plosone: 0033250
The Royal Society of Chemistry miRNA-mediated alteration of sulfatase modifying factor 1 expression using self-assembled branched DNA nanostructures
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC879Hu01 Recombinant Sulfatase Modifying Factor 1 (SUMF1) Positive Control; Immunogen; SDS-PAGE; WB.
PAC879Hu01 Polyclonal Antibody to Sulfatase Modifying Factor 1 (SUMF1) WB
MAC879Hu22 Monoclonal Antibody to Sulfatase Modifying Factor 1 (SUMF1) WB; IHC; ICC; IP.
SEC879Hu ELISA Kit for Sulfatase Modifying Factor 1 (SUMF1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC879Hu Multiplex Assay Kit for Sulfatase Modifying Factor 1 (SUMF1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMC879Hu Multiplex Assay Kit for Sulfatase Modifying Factor 1 (SUMF1) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.