Multiplex Assay Kit for Peroxiredoxin 1 (PRDX1) ,etc. by CBA (Cytometric Bead Array)

MSP23; NKEFA; PAG; PAGA; PAGB; TDPX2; Natural killer cell-enhancing factor A; Proliferation-associated; Thioredoxin peroxidase 2; Thioredoxin-dependent peroxide reductase 2

Specificity

This assay has high sensitivity and excellent specificity for detection of Peroxiredoxin 1 (PRDX1) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Peroxiredoxin 1 (PRDX1) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Peroxiredoxin 1 (PRDX1) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Peroxiredoxin 1 (PRDX1) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 91-101 94
EDTA plasma(n=5) 81-95 89
heparin plasma(n=5) 88-102 94

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Peroxiredoxin 1 (PRDX1) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Peroxiredoxin 1 (PRDX1) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Peroxiredoxin 1 (PRDX1) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 93-104% 79-96% 92-101% 87-95%
EDTA plasma(n=5) 81-89% 89-104% 78-90% 80-102%
heparin plasma(n=5) 97-105% 92-101% 92-99% 95-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
PLOS ONE Susceptibility to COPD: Differential Proteomic Profiling after Acute Smoking Pubmed:25036363
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPC749Ra01 Recombinant Peroxiredoxin 1 (PRDX1) Positive Control; Immunogen; SDS-PAGE; WB.
PAC749Ra01 Polyclonal Antibody to Peroxiredoxin 1 (PRDX1) WB; IHC; ICC; IP.
MAC749Ra21 Monoclonal Antibody to Peroxiredoxin 1 (PRDX1) WB; IHC; ICC; IP.
SEC749Ra ELISA Kit for Peroxiredoxin 1 (PRDX1) Enzyme-linked immunosorbent assay for Antigen Detection.
CMC749Ra Multiplex Assay Kit for Peroxiredoxin 1 (PRDX1) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMC749Ra Multiplex Assay Kit for Peroxiredoxin 1 (PRDX1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.