Multiplex Assay Kit for Zyxin (ZYX) ,etc. by CBA (Cytometric Bead Array)

ESP2; HED2

Specificity

This assay has high sensitivity and excellent specificity for detection of Zyxin (ZYX) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Zyxin (ZYX) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Zyxin (ZYX) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Zyxin (ZYX) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 94-101 98
EDTA plasma(n=5) 87-104 91
heparin plasma(n=5) 99-105 102

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Zyxin (ZYX) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Zyxin (ZYX) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Zyxin (ZYX) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 84-97% 86-94% 80-89%
EDTA plasma(n=5) 79-99% 92-105% 82-89% 88-95%
heparin plasma(n=5) 91-101% 94-103% 80-98% 95-102%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC235Hu02 Recombinant Zyxin (ZYX) Positive Control; Immunogen; SDS-PAGE; WB.
RPC235Hu01 Recombinant Zyxin (ZYX) Positive Control; Immunogen; SDS-PAGE; WB.
PAC235Hu01 Polyclonal Antibody to Zyxin (ZYX) WB,IHC
PAC235Hu02 Polyclonal Antibody to Zyxin (ZYX) WB
LAC235Hu71 Biotin-Linked Polyclonal Antibody to Zyxin (ZYX) WB
LAC235Hu81 FITC-Linked Polyclonal Antibody to Zyxin (ZYX) WB; IHC; ICC; IF.
MAC235Hu21 Monoclonal Antibody to Zyxin (ZYX) WB
MAC235Hu25 Monoclonal Antibody to Zyxin (ZYX) WB
MAC235Hu26 Monoclonal Antibody to Zyxin (ZYX) WB
SEC235Hu ELISA Kit for Zyxin (ZYX) Enzyme-linked immunosorbent assay for Antigen Detection.
CMC235Hu Multiplex Assay Kit for Zyxin (ZYX) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMC235Hu Multiplex Assay Kit for Zyxin (ZYX) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.