Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Diacylglycerol (DAG) ,etc. by CBA (Cytometric Bead Array)
DG; Diglyceride
- Product No.CMC038Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length3h
- Detection Range97.6563-100000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 32.5521pg/mL.
- DownloadInstruction Manual
- UOM 48T96T
- FOB
US$ 685
US$ 979
For more details, please contact local distributors!
Specificity
This assay has high sensitivity and excellent specificity for detection of Diacylglycerol (DAG) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Diacylglycerol (DAG) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of Diacylglycerol (DAG) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Diacylglycerol (DAG) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 86-99 | 93 |
| EDTA plasma(n=5) | 99-105 | 102 |
| heparin plasma(n=5) | 79-104 | 87 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Diacylglycerol (DAG) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Diacylglycerol (DAG) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Diacylglycerol (DAG) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 92-102% | 95-105% | 84-91% | 95-104% |
| EDTA plasma(n=5) | 94-103% | 87-95% | 96-105% | 79-103% |
| heparin plasma(n=5) | 80-93% | 99-105% | 78-101% | 92-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:DAG) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
| Magazine | Citations |
| Acta Pharmacologica Sinica | Wogonin ameliorates lipotoxicity-induced apoptosis of cultured vascular smooth muscle cells via interfering with DAG-PKC pathway Nature: 2011120a |
| Psychoneuroendocrinology | Maternal stress predicts altered biogenesis and the profile of mitochondrial proteins in the frontal cortex and hippocampus of adult offspring rats PubMed: 26143539 |
| The Journal of Biological Chemistry | Aryl Hydrocarbon Receptor Plays Protective Roles against High Fat Diet (HFD)-induced Hepatic Steatosis and the Subsequent Lipotoxicity via Direct Transcriptional ReCavia (Guinea pig )lation of Socs3 Gene Expression Pubmed:26865635 |
| Journal of the American Heart Association | Pigment Epithelium-Derived Factor (PEDF) Improves Ischemic Cardiac Functional Reserve Through Decreasing Hypoxic Cardiomyocyte Contractility Through PEDF Receptor (PEDF-R). pubmed:27413044 |
| International Journal of Molecular Medicine | PEDF protects cardiomyocytes by promoting FUNDC1‑mediated mitophagy via PEDF-R under hypoxic condition Pubmed:29512692 |
| British Journal of Pharmacology | Bouchardatine analogue alleviates NAFLD/NASH in high fat fed mice via blunting ATP synthase activity Pubmed: 31113010 |
| Gut Akkermansia muciniphila ameliorates non-alcoholic fatty liver disease by L-aspartate via interaction with liver | |
| Histochem Cell Biol | The expression of diacylglycerol kinase isoforms α and ζ correlates with the progression of experimental autoimmune encephalomyelitis in rats 34312706 |
| Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
| CPC038Ge11 | BSA Conjugated Diacylglycerol (DAG) | Immunogen; SDS-PAGE; WB. |
| CPC038Ge21 | OVA Conjugated Diacylglycerol (DAG) | Immunogen; SDS-PAGE; WB. |
| PAC038Ge01 | Polyclonal Antibody to Diacylglycerol (DAG) | ELISA |
| LAC038Ge71 | Biotin-Linked Polyclonal Antibody to Diacylglycerol (DAG) | WB; IHC; ICC. |
| CEC038Ge | ELISA Kit for Diacylglycerol (DAG) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| CMC038Ge | Multiplex Assay Kit for Diacylglycerol (DAG) ,etc. by CBA (Cytometric Bead Array) | FLIA Kit for Antigen Detection. |
| LMC038Ge | Multiplex Assay Kit for Diacylglycerol (DAG) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |

