Multiplex Assay Kit for Transferrin (TF) ,etc. by CBA (Cytometric Bead Array)

TRF; Siderophilin; Serotransferrin; Beta-1 metal-binding globulin

Specificity

This assay has high sensitivity and excellent specificity for detection of Transferrin (TF) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Transferrin (TF) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Transferrin (TF) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Transferrin (TF) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 91-98 94
EDTA plasma(n=5) 86-96 90
heparin plasma(n=5) 82-99 94

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Transferrin (TF) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Transferrin (TF) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Transferrin (TF) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 90-101% 90-97% 95-102%
EDTA plasma(n=5) 97-105% 89-104% 81-97% 79-96%
heparin plasma(n=5) 93-104% 80-95% 89-98% 90-97%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
PLoS ONE Identification of Altered Plasma Proteins by Proteomic Study in Valvular Heart Diseases and the Potential Clinical Significance PubMed: PMC3754973
Physiological research The Labile Iron Pool in Monocytes Reflects the Activity of the Atherosclerotic Process in Men with Chronic Cardiovascular Disease pubmed:27782743
Journal of Proteomics Putative salivary biomarkers useful to differentiate patients with fibromyalgia Pubmed:29654921
Journal of Clinical Medicine Urinary Proteomics for the Early Diagnosis of Diabetic Nephropathy in Taiwanese Patients Pubmed: 30486327
The Nigerian postgraduate medical journal the official publication of the National Postgraduate Medical College of Nigeria Assessment of iron deficiency anaemia and its risk factors among adults with chronic kidney disease in a tertiary hospital in Nigeria
Haematologica New thiazolidinones reduce iron overload in mouse models of hereditary hemochromatosis and β-thalassemia Pubmed: 30792208
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
NPC036Hu01 Native Transferrin (TF) Positive Control; Immunogen; SDS-PAGE; WB.
RPC036Hu01 Recombinant Transferrin (TF) Positive Control; Immunogen; SDS-PAGE; WB.
PAC036Hu02 Polyclonal Antibody to Transferrin (TF) WB; IHC; ICC/IF
PAC036Hu05 Polyclonal Antibody to Transferrin (TF) WB; IHC
PAC036Hu01 Polyclonal Antibody to Transferrin (TF) WB,IHC
LAC036Hu81 FITC-Linked Polyclonal Antibody to Transferrin (TF) WB; IHC; ICC; IF.
LAC036Hu71 Biotin-Linked Polyclonal Antibody to Transferrin (TF) WB
MAC036Hu21 Monoclonal Antibody to Transferrin (TF) WB; IHC; ICC/IF
MAC036Hu25 Monoclonal Antibody to Transferrin (TF) WB; ICC/IF
MAC036Hu24 Monoclonal Antibody to Transferrin (TF) WB; IHC
MAC036Hu27 Monoclonal Antibody to Transferrin (TF) WB
MAC036Hu29 Monoclonal Antibody to Transferrin (TF) WB; ICC/IF
MAC036Hu23 Monoclonal Antibody to Transferrin (TF) WB; IHC
MAC036Hu22 Monoclonal Antibody to Transferrin (TF) WB
MAC036Hu26 Monoclonal Antibody to Transferrin (TF) WB
FAC036Hu02 Anti-Transferrin (TF) Monoclonal Antibody FCM
LAC036Hu72 Biotin-Linked Monoclonal Antibody to Transferrin (TF) WB
LAC036Hu82 FITC-Linked Monoclonal Antibody to Transferrin (TF) WB; IHC; ICC; IF.
SEC036Hu ELISA Kit for Transferrin (TF) Enzyme-linked immunosorbent assay for Antigen Detection.
HEC036Hu High Sensitive ELISA Kit for Transferrin (TF) Enzyme-linked immunosorbent assay for Antigen Detection.
SCC036Hu CLIA Kit for Transferrin (TF) Chemiluminescent immunoassay for Antigen Detection.
LMC036Hu Multiplex Assay Kit for Transferrin (TF) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMC036Hu Multiplex Assay Kit for Transferrin (TF) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
KSC036Hu01 ELISA Kit DIY Materials for Transferrin (TF) Main materials for "Do It (ELISA Kit) Yourself".