Multiplex Assay Kit for Cyclin Dependent Kinase 1 (CDK1) ,etc. by CBA (Cytometric Bead Array)

CDC2; CDC28A; CDK1; CDC28-A; CDKN1; P34CDC2; p34 protein kinase; Cell Division Control Protein 2 Homolog; Cell Division Cycle 2,G1 To S And G2 To M

Specificity

This assay has high sensitivity and excellent specificity for detection of Cyclin Dependent Kinase 1 (CDK1) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Cyclin Dependent Kinase 1 (CDK1) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Cyclin Dependent Kinase 1 (CDK1) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Cyclin Dependent Kinase 1 (CDK1) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-95 84
EDTA plasma(n=5) 97-104 101
heparin plasma(n=5) 78-101 91

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cyclin Dependent Kinase 1 (CDK1) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cyclin Dependent Kinase 1 (CDK1) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cyclin Dependent Kinase 1 (CDK1) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 90-99% 92-105% 84-104% 93-102%
EDTA plasma(n=5) 82-104% 89-97% 99-105% 86-93%
heparin plasma(n=5) 79-102% 97-105% 98-105% 80-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
The effect of vitrification after warming on the expressions of p38, CDK1, and cyclin B in immature goat oocytes followed by in vitro maturation
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB888Hu01 Recombinant Cyclin Dependent Kinase 1 (CDK1) Positive Control; Immunogen; SDS-PAGE; WB.
PAB888Hu01 Polyclonal Antibody to Cyclin Dependent Kinase 1 (CDK1) WB
FAB888Hu01 Anti-Cyclin Dependent Kinase 1 (CDK1) Polyclonal Antibody FCM
LAB888Hu71 Biotin-Linked Polyclonal Antibody to Cyclin Dependent Kinase 1 (CDK1) WB
MAB888Hu22 Monoclonal Antibody to Cyclin Dependent Kinase 1 (CDK1) Testing in progress
SEB888Hu ELISA Kit for Cyclin Dependent Kinase 1 (CDK1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB888Hu Multiplex Assay Kit for Cyclin Dependent Kinase 1 (CDK1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMB888Hu Multiplex Assay Kit for Cyclin Dependent Kinase 1 (CDK1) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.