Multiplex Assay Kit for Troponin T (TNT) ,etc. by CBA (Cytometric Bead Array)

Tn-T; TNNT

Specificity

This assay has high sensitivity and excellent specificity for detection of Troponin T (TNT) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Troponin T (TNT) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Troponin T (TNT) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Troponin T (TNT) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-104 92
EDTA plasma(n=5) 95-102 98
heparin plasma(n=5) 81-95 85

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Troponin T (TNT) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Troponin T (TNT) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Troponin T (TNT) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 92-102% 93-105% 89-103% 94-105%
EDTA plasma(n=5) 92-102% 78-93% 94-101% 80-104%
heparin plasma(n=5) 93-101% 93-101% 88-99% 88-96%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
IJC Heart & Vasculature Cardiovascular changes in patients with non-severe Plasmodium vivax malaria article:S2352-9067(16)30010-0
Journal of the American Heart Association Postinfarction Hearts Are Protected by Premature Senescent Cardiomyocytes Via GATA 4‐Dependent CCN 1 Secretion
Experimental Gerontology Neural control of postural sway: relationship to strength measures in young and elderly adults Pubmed: 30630036
Nature Communications Preclinical development of a miR-132 inhibitor for heart failure treatment Pubmed: 32005803
Scientific Reports Cardioprotective effect of grape polyphenol extract against doxorubicin induced cardiotoxicity Pubmed: 32895481
Molecular Medicine Reports The mRNA expression of Il6 and Pdcd1 are predictive and protective factors for doxorubicin?induced cardiotoxicity 33300057
Cell Metabolism Pharmacological inhibition of arachidonate 12-lipoxygenase ameliorates myocardial ischemia-reperfusion injury in multiple species 34536344
Catalog No. Related products for research use of Oryctolagus cuniculus (Rabbit) Organism species Applications (RESEARCH USE ONLY!)
SEB820Rb ELISA Kit for Troponin T (TNT) Enzyme-linked immunosorbent assay for Antigen Detection.
CMB820Rb Multiplex Assay Kit for Troponin T (TNT) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMB820Rb Multiplex Assay Kit for Troponin T (TNT) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.