Multiplex Assay Kit for Signal Transducer And Activator Of Transcription 3 (STAT3) ,etc. by CBA (Cytometric Bead Array)

APRF; Acute-Phase Response Factor

Specificity

This assay has high sensitivity for detection of Signal Transducer And Activator Of Transcription 3 (STAT3) ,etc. by CBA (Cytometric Bead Array).
100% cross-reactivity of Signal Transducer And Activator Of Transcription 3 (STAT3) ,etc. by CBA (Cytometric Bead Array) was observed among .

Recovery

Matrices listed below were spiked with certain level of recombinant Signal Transducer And Activator Of Transcription 3 (STAT3) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Signal Transducer And Activator Of Transcription 3 (STAT3) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 97-105 101
EDTA plasma(n=5) 93-104 101
heparin plasma(n=5) 78-88 82

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Signal Transducer And Activator Of Transcription 3 (STAT3) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Signal Transducer And Activator Of Transcription 3 (STAT3) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Signal Transducer And Activator Of Transcription 3 (STAT3) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 90-98% 96-103% 79-92% 80-90%
EDTA plasma(n=5) 83-103% 88-97% 78-104% 80-90%
heparin plasma(n=5) 88-103% 94-102% 85-97% 82-98%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Pharmaceutics Oleacein and Foam Cell Formation in Human Monocyte-Derived Macrophages: A Potential Strategy Against Early and Advanced Atherosclerotic Lesions Pubmed: 32283795
CLINICAL IMMUNOLOGY Serum ERK1/2 proteins fluctuating with HBV infection report frequency of viral-specific CD8+ T cells and predict IFNα therapeutic effect in chronic hepatitis B patients Pubmed: 32791312
Catalog No. Related products for research use of Organism species Applications (RESEARCH USE ONLY!)
RPB743Mi01 Recombinant Signal Transducer And Activator Of Transcription 3 (STAT3) Positive Control; Immunogen; SDS-PAGE; WB.
RPB743Mi02 Recombinant Signal Transducer And Activator Of Transcription 3 (STAT3) Positive Control; Immunogen; SDS-PAGE; WB.
RPB743Mi03 Recombinant Signal Transducer And Activator Of Transcription 3 (STAT3) Positive Control; Immunogen; SDS-PAGE; WB.
RPB743Mi04 Recombinant Signal Transducer And Activator Of Transcription 3 (STAT3) Positive Control; Immunogen; SDS-PAGE; WB.
RPB743Mi05 Recombinant Signal Transducer And Activator Of Transcription 3 (STAT3) Positive Control; Immunogen; SDS-PAGE; WB.
PAB743Mi03 Polyclonal Antibody to Signal Transducer And Activator Of Transcription 3 (STAT3) WB; ICC/IF
PAB743Mi01 Polyclonal Antibody to Signal Transducer And Activator Of Transcription 3 (STAT3) WB,IHC
PAB743Mi02 Polyclonal Antibody to Signal Transducer And Activator Of Transcription 3 (STAT3) IHC; ICC/IF
PAB743Mi04 Polyclonal Antibody to Signal Transducer And Activator Of Transcription 3 (STAT3) WB; IHC
PAB743Mi05 Polyclonal Antibody to Signal Transducer And Activator Of Transcription 3 (STAT3) WB; IHC; ICC; IP.
MAB743Mi27 Monoclonal Antibody to Signal Transducer And Activator Of Transcription 3 (STAT3) ICC/IF
MAB743Mi22 Monoclonal Antibody to Signal Transducer And Activator Of Transcription 3 (STAT3) WB; IHC
MAB743Mi23 Monoclonal Antibody to Signal Transducer And Activator Of Transcription 3 (STAT3) WB; IHC
MAB743Mi24 Monoclonal Antibody to Signal Transducer And Activator Of Transcription 3 (STAT3) WB; IHC
MAB743Mi21 Monoclonal Antibody to Signal Transducer And Activator Of Transcription 3 (STAT3) WB; IHC
MAB743Mi25 Monoclonal Antibody to Signal Transducer And Activator Of Transcription 3 (STAT3) WB; IHC
SEB743Mi ELISA Kit for Signal Transducer And Activator Of Transcription 3 (STAT3) Enzyme-linked immunosorbent assay for Antigen Detection.
CMB743Mi Multiplex Assay Kit for Signal Transducer And Activator Of Transcription 3 (STAT3) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMB743Mi Multiplex Assay Kit for Signal Transducer And Activator Of Transcription 3 (STAT3) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.