Multiplex Assay Kit for Lactate Dehydrogenase B (LDHB) ,etc. by CBA (Cytometric Bead Array)

LDH-B; LDH-H; Renal carcinoma antigen NY-REN-46

Specificity

This assay has high sensitivity and excellent specificity for detection of Lactate Dehydrogenase B (LDHB) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Lactate Dehydrogenase B (LDHB) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Lactate Dehydrogenase B (LDHB) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Lactate Dehydrogenase B (LDHB) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-102 94
EDTA plasma(n=5) 82-92 86
heparin plasma(n=5) 78-97 85

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Lactate Dehydrogenase B (LDHB) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Lactate Dehydrogenase B (LDHB) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Lactate Dehydrogenase B (LDHB) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-89% 89-101% 84-91% 85-104%
EDTA plasma(n=5) 84-101% 96-104% 92-101% 92-103%
heparin plasma(n=5) 79-105% 90-101% 79-95% 78-93%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Proteome Science Proteomic analysis of effluents from perfused human heart for transplantation: identification of potential biomarkers for ischemic heart damag Proteomesci: 14775956
PLoS One Presence in the Pre-Surgical Fine-Needle Aspiration of Potential Thyroid Biomarkers Previously Identified in the Post-Surgical One PubMed: PMC3765839
Autophagy LDHB inhibition induces mitophagy and facilitates the progression of CSFV infection Pubmed: 32924761
Cell Death Discovery Fecal microbiota transplantation from patients with autoimmune encephalitis modulates Th17 response and relevant behaviors in mice Pubmed: 32821439
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPB698Mu02 Recombinant Lactate Dehydrogenase B (LDHB) Positive Control; Immunogen; SDS-PAGE; WB.
RPB698Mu01 Recombinant Lactate Dehydrogenase B (LDHB) Positive Control; Immunogen; SDS-PAGE; WB.
PAB698Mu02 Polyclonal Antibody to Lactate Dehydrogenase B (LDHB) WB; IHC; ICC; IP.
PAB698Mu01 Polyclonal Antibody to Lactate Dehydrogenase B (LDHB) WB,IHC
LAB698Mu81 FITC-Linked Polyclonal Antibody to Lactate Dehydrogenase B (LDHB) WB; IHC; ICC; IF.
LAB698Mu71 Biotin-Linked Polyclonal Antibody to Lactate Dehydrogenase B (LDHB) WB
SEB698Mu ELISA Kit for Lactate Dehydrogenase B (LDHB) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB698Mu Multiplex Assay Kit for Lactate Dehydrogenase B (LDHB) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMB698Mu Multiplex Assay Kit for Lactate Dehydrogenase B (LDHB) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.