Multiplex Assay Kit for Androgen Receptor (AR) ,etc. by CBA (Cytometric Bead Array)

AIS; DHTR; HUMARA; KD; NR3C4; SBMA; SMAX1; TFM; Dihydrotestosterone receptor; Nuclear Receptor Subfamily 3,Group C,Member 4; Testicular Feminization; Kennedy Disease

Specificity

This assay has high sensitivity and excellent specificity for detection of Androgen Receptor (AR) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Androgen Receptor (AR) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Androgen Receptor (AR) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Androgen Receptor (AR) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 92-101 97
EDTA plasma(n=5) 78-103 83
heparin plasma(n=5) 80-105 90

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Androgen Receptor (AR) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Androgen Receptor (AR) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Androgen Receptor (AR) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 91-99% 79-90% 84-92% 83-91%
EDTA plasma(n=5) 81-97% 99-105% 83-104% 80-93%
heparin plasma(n=5) 79-92% 80-97% 83-101% 98-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Cardiometry Modifying effect of obesity on the content of sex hormones and their receptors in endometrial adenocarcinoma and its surrounding tissue
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPB252Mu01 Recombinant Androgen Receptor (AR) Positive Control; Immunogen; SDS-PAGE; WB.
PAB252Mu02 Polyclonal Antibody to Androgen Receptor (AR) WB; IHC; ICC; IP.
PAB252Mu01 Polyclonal Antibody to Androgen Receptor (AR) IHC
SEB252Mu ELISA Kit for Androgen Receptor (AR) Enzyme-linked immunosorbent assay for Antigen Detection.
CMB252Mu Multiplex Assay Kit for Androgen Receptor (AR) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMB252Mu Multiplex Assay Kit for Androgen Receptor (AR) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.