Multiplex Assay Kit for Plasminogen (Plg) ,etc. by CBA (Cytometric Bead Array)
PL; Plasmin; Activation peptide; Angiostatin
- Product No.CMB236Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length4h
- Detection Range0.9766-1000ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.3255ng/mL.
- DownloadInstruction Manual
- UOM 48T96T
- FOB
US$ 606
US$ 866
For more details, please contact local distributors!
Specificity
This assay has high sensitivity and excellent specificity for detection of Plasminogen (Plg) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Plasminogen (Plg) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Plasminogen (Plg) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Plasminogen (Plg) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 92-105 | 101 |
| EDTA plasma(n=5) | 97-105 | 101 |
| heparin plasma(n=5) | 93-101 | 96 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Plasminogen (Plg) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Plasminogen (Plg) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Plasminogen (Plg) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 99-105% | 85-99% | 92-101% | 82-105% |
| EDTA plasma(n=5) | 82-90% | 97-105% | 89-101% | 98-105% |
| heparin plasma(n=5) | 90-102% | 80-101% | 87-95% | 92-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
| Magazine | Citations |
| International Journal of Molecular Sciences | The Anticoagulant Effect of PGI2S and tPA in Transgenic Umbilical Vein Endothelial Cells Is Linked to Up-Regulation of PKA and PKC Mdpi: Source |
| J Anim Physiol Anim Nutr (Berl). | Improved milk production through PG-PL system by provision of in-house shelter management in lactating Murrah buffaloes during winter season. pubmed:28084661 |
| Neurotherapeutics | iTRAQ-Based Quantitative Proteomics Reveals the New Evidence Base for Traumatic Brain Injury Treated with Targeted Temperature Management pubmed:29247448 |
| Veterinarski Arhiv | The influence of a modified micro-environment on stress and milk production through the plasminogen-plasmin system in Murrah buffaloes during the hot-humid … 10.24099:vet.arhiv.170113 |
| Food Bioscience | Reducing antigenicity of ¦Â-lactoglobulin, probiotic properties and safety evaluation of Lactobacillus plantarum AHQ-14 and Lactobacillus bulgaricus BD0390 |
| Foods | Antigenicity and Safety Evaluation of Lactiplantibacillus plantarum 7-2 Screened to Reduce α-Casein Antigen Pubmed:35010214 |
| Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
| RPB236Ra01 | Recombinant Plasminogen (Plg) | Positive Control; Immunogen; SDS-PAGE; WB. |
| APB236Ra01 | Active Plasminogen (Plg) | Cell culture; Activity Assays. |
| PAB236Ra01 | Polyclonal Antibody to Plasminogen (Plg) | WB; IHC |
| FAB236Ra01 | Anti-Plasminogen (Plg) Polyclonal Antibody | FCM |
| MAB236Ra21 | Monoclonal Antibody to Plasminogen (Plg) | WB |
| MAB236Ra22 | Monoclonal Antibody to Plasminogen (Plg) | WB |
| SEB236Ra | ELISA Kit for Plasminogen (Plg) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| CMB236Ra | Multiplex Assay Kit for Plasminogen (Plg) ,etc. by CBA (Cytometric Bead Array) | FLIA Kit for Antigen Detection. |
| LMB236Ra | Multiplex Assay Kit for Plasminogen (Plg) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
| KSB236Ra01 | ELISA Kit DIY Materials for Plasminogen (Plg) | Main materials for "Do It (ELISA Kit) Yourself". |