Multiplex Assay Kit for Cluster Of Differentiation 4 (CD4) ,etc. by CBA (Cytometric Bead Array)

CD4mut; p55; T-cell surface glycoprotein CD4; T-cell surface antigen T4/Leu-3

Specificity

This assay has high sensitivity and excellent specificity for detection of Cluster Of Differentiation 4 (CD4) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Cluster Of Differentiation 4 (CD4) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Cluster Of Differentiation 4 (CD4) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Cluster Of Differentiation 4 (CD4) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 96-103 99
EDTA plasma(n=5) 82-103 86
heparin plasma(n=5) 92-101 96

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cluster Of Differentiation 4 (CD4) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cluster Of Differentiation 4 (CD4) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cluster Of Differentiation 4 (CD4) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-94% 98-105% 88-96% 78-101%
EDTA plasma(n=5) 92-99% 81-101% 96-103% 98-105%
heparin plasma(n=5) 91-99% 80-96% 88-96% 90-97%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Taylor & Francis Influences of Hyriopsis cumingii polysaccharides on mice immunosignaling molecules and T lymphocyte differentiation 09540105.2017.1306494
anticancer research Adjuvant Postoperative CD40 Agonist and PD-1 Antagonist Combination Therapy in Syngeneic Tongue Cancer Mouse Model Pubmed: 32366416
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB167Hu01 Recombinant Cluster Of Differentiation 4 (CD4) Positive Control; Immunogen; SDS-PAGE; WB.
PAB167Hu01 Polyclonal Antibody to Cluster Of Differentiation 4 (CD4) ICC/IF
FAB167Hu01 Anti-Cluster Of Differentiation 4 (CD4) Polyclonal Antibody Flow cytometry.
LAB167Hu71 Biotin-Linked Polyclonal Antibody to Cluster Of Differentiation 4 (CD4) WB; IHC; ICC.
FAB167Hu41 PE-Linked Anti-Cluster Of Differentiation 4 (CD4) Polyclonal Antibody Flow cytometry.
FAB167Hu51 APC-Linked Anti-Cluster Of Differentiation 4 (CD4) Polyclonal Antibody Flow cytometry.
FAB167Hu81 FITC-Linked Anti-Cluster Of Differentiation 4 (CD4) Polyclonal Antibody Flow cytometry.
MAB167Hu22 Monoclonal Antibody to Cluster Of Differentiation 4 (CD4) WB; ICC/IF
RAB167Hu22 Recombinant Antibody to Cluster Of Differentiation 4 (CD4) FCM
MAB167Hu23 Monoclonal Antibody to Cluster Of Differentiation 4 (CD4) IHC; ICC/IF
MAB167Hu24 Monoclonal Antibody to Cluster Of Differentiation 4 (CD4) WB; IHC; ICC/IF
MAB167Hu26 Monoclonal Antibody to Cluster Of Differentiation 4 (CD4) ICC/IF
MAB167Hu27 Monoclonal Antibody to Cluster Of Differentiation 4 (CD4) ICC/IF
MAB167Hu21 Monoclonal Antibody to Cluster Of Differentiation 4 (CD4) WB
RAB167Hu21 Recombinant Antibody to Cluster Of Differentiation 4 (CD4) WB; IHC; ICC.
MAB167Hu25 Monoclonal Antibody to Cluster Of Differentiation 4 (CD4) WB
FAB167Hu02 Anti-Cluster Of Differentiation 4 (CD4) Monoclonal Antibody FCM
FAB167Hu42 PE-Linked Anti-Cluster Of Differentiation 4 (CD4) Monoclonal Antibody FCM
FAB167Hu52 APC-Linked Anti-Cluster Of Differentiation 4 (CD4) Monoclonal Antibody WB; IHC
FAB167Hu82 FITC-Linked Anti-Cluster Of Differentiation 4 (CD4) Monoclonal Antibody FCM
SEB167Hu ELISA Kit for Cluster Of Differentiation 4 (CD4) Enzyme-linked immunosorbent assay for Antigen Detection.
CMB167Hu Multiplex Assay Kit for Cluster Of Differentiation 4 (CD4) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMB167Hu Multiplex Assay Kit for Cluster Of Differentiation 4 (CD4) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSB167Hu01 ELISA Kit DIY Materials for Cluster Of Differentiation 4 (CD4) Main materials for "Do It (ELISA Kit) Yourself".