Multiplex Assay Kit for Alpha-1-Antichymotrypsin (a1ACT) ,etc. by CBA (Cytometric Bead Array)

A1-ACT; SERPINA3; AACT; ACT; GIG24; GIG25; Serpin Peptidase Inhibitor Clade A Member 3(Alpha-1 Antiproteinase; Antitrypsin); Cell growth-inhibiting gene 24/25 protein

Specificity

This assay has high sensitivity and excellent specificity for detection of Alpha-1-Antichymotrypsin (a1ACT) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Alpha-1-Antichymotrypsin (a1ACT) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Alpha-1-Antichymotrypsin (a1ACT) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Alpha-1-Antichymotrypsin (a1ACT) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-98 87
EDTA plasma(n=5) 95-102 98
heparin plasma(n=5) 82-104 94

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Alpha-1-Antichymotrypsin (a1ACT) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Alpha-1-Antichymotrypsin (a1ACT) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Alpha-1-Antichymotrypsin (a1ACT) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-95% 90-101% 94-105% 83-98%
EDTA plasma(n=5) 95-103% 85-102% 90-98% 86-101%
heparin plasma(n=5) 92-105% 80-92% 96-105% 78-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
PLoS ONE Identification of Altered Plasma Proteins by Proteomic Study in Valvular Heart Diseases and the Potential Clinical Significance PubMed: PMC3754973
Mainz Identifizierung neuer potentieller Biomarker für das Kolonkarzinom sowie dessen Vorstufen Info:Source
義守大學生物技術與化學工程研究所學位論文 可拋棄式退化性關節炎電化學式尿液免疫感測器之研究 Electrochemical Immunosensor Detection of Urinary Biomaker for Osteoarthritis Diagnosis Publication: U0074-2807201500521300
疾病监测 羊瘙痒因子139A感染引起小鼠脑组织中的α1-ACT表达增加 CJFDLAST2017
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
SEB015Ra ELISA Kit for Alpha-1-Antichymotrypsin (a1ACT) Enzyme-linked immunosorbent assay for Antigen Detection.
CMB015Ra Multiplex Assay Kit for Alpha-1-Antichymotrypsin (a1ACT) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMB015Ra Multiplex Assay Kit for Alpha-1-Antichymotrypsin (a1ACT) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.