Multiplex Assay Kit for High Density Lipoprotein (HDL) ,etc. by CBA (Cytometric Bead Array)

Specificity

This assay has high sensitivity and excellent specificity for detection of High Density Lipoprotein (HDL) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between High Density Lipoprotein (HDL) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant High Density Lipoprotein (HDL) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of High Density Lipoprotein (HDL) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 81-90 87
EDTA plasma(n=5) 96-103 99
heparin plasma(n=5) 81-98 90

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Density Lipoprotein (HDL) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Density Lipoprotein (HDL) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of High Density Lipoprotein (HDL) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 90-101% 97-105% 80-94%
EDTA plasma(n=5) 87-104% 78-101% 78-99% 96-105%
heparin plasma(n=5) 83-92% 78-104% 82-105% 88-96%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Iranian Journal of Health and Physical activity Effects of Aerobic Training, with or without Zizyphus Jujuba Water Extraction, on Fundus Nesfatin-1, ATP, HDL-C, and LDL-C Concentrations in Female Rats Ijvst: Source
Scandinavian Journal of Medicine & Science in Sports Endurance training selectively increases HDL-bound sphingosine-1-phosphate in the plasma pubmed:28493600
Journal of Nutritional Science and Vitaminology (Tokyo) Anthocyanin Cyanidin-3-Glucoside Attenuates Platelet Granule Release in Mice Fed High-Fat Diets. pubmed:28978870
RESPIRATORY RESEARCH The HDL from septic-ARDS patients with composition changes exacerbates pulmonary endothelial dysfunction and acute lung injury induced by cecal ligation … Pubmed: 33148285
respiratory research The adverse alterations of HDL in quality promote septic ARDS via exacerbated pulmonary endothelial dysfunction
Diabetes Metab Syndr Obes ¡°Adjusting Internal Organs and Dredging Channel¡± Electroacupuncture Ameliorates Insulin Resistance in Type 2 Diabetes Mellitus by Regulating the Intestinal?¡­ 34135611
Evid Based Complement Alternat Med Effect of Acupoint Embedding on Serum Leptin and Hypothalamus Leptin Receptor Expression in Rats with Simple Obesity 34659432
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
SEB006Ra ELISA Kit for High Density Lipoprotein (HDL) Enzyme-linked immunosorbent assay for Antigen Detection.
CMB006Ra Multiplex Assay Kit for High Density Lipoprotein (HDL) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMB006Ra Multiplex Assay Kit for High Density Lipoprotein (HDL) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.