Multiplex Assay Kit for P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc. by CBA (Cytometric Bead Array)

CD162; SELPLG; CLA; Selectin P Ligand

Specificity

This assay has high sensitivity and excellent specificity for detection of P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-94 90
EDTA plasma(n=5) 93-101 96
heparin plasma(n=5) 78-105 88

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 95-103% 95-103% 93-102% 92-99%
EDTA plasma(n=5) 88-96% 99-105% 81-103% 88-101%
heparin plasma(n=5) 79-96% 97-105% 88-96% 89-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Molecular Nutrition & Food Research Endoplasmic reticulum stress contributes to ferritin molecules-mediated macrophage migrationvia P-selectin glycoprotein ligand-1. pubmed:27813270
parasite immunology The intestinal nematode inhibits T‐cell reactivity by targeting P‐GP activity pubmed:29063624
Scientific Reports Adhesion of Toxoplasma gondii tachyzoite-infected vehicle leukocytes to capillary endothelial cells triggers timely parasite egression pubmed:28720868
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPA985Ra01 Recombinant P-Selectin Glycoprotein Ligand 1 (PSGL1) Positive Control; Immunogen; SDS-PAGE; WB.
PAA985Ra01 Polyclonal Antibody to P-Selectin Glycoprotein Ligand 1 (PSGL1) WB; IHC; ICC; IP.
MAA985Ra21 Monoclonal Antibody to P-Selectin Glycoprotein Ligand 1 (PSGL1) WB; IHC; ICC; IP.
SEA985Ra ELISA Kit for P-Selectin Glycoprotein Ligand 1 (PSGL1) Enzyme-linked immunosorbent assay for Antigen Detection.
CMA985Ra Multiplex Assay Kit for P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMA985Ra Multiplex Assay Kit for P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.