Multiplex Assay Kit for Acetylcholine (ACH) ,etc. by CBA (Cytometric Bead Array)

Specificity

This assay has high sensitivity and excellent specificity for detection of Acetylcholine (ACH) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Acetylcholine (ACH) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of Acetylcholine (ACH) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Acetylcholine (ACH) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 98-105 102
EDTA plasma(n=5) 90-98 95
heparin plasma(n=5) 92-101 95

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Acetylcholine (ACH) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Acetylcholine (ACH) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Acetylcholine (ACH) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-102% 78-93% 87-103% 83-92%
EDTA plasma(n=5) 82-101% 99-105% 87-101% 78-104%
heparin plasma(n=5) 92-99% 87-95% 80-92% 96-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:ACH) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Neurosci Bull Combined administration of D-galactose and aluminium induces Alzheimer-like lesions in brain PubMed: 21614097
Molecular Neurobiology Neuroprotective effects of simvastatin and Cilostazol in L-methionine-induced vascular dementia in rats pubmed:27544235
Turk Kardiyol Dern Ars.  Effect of statins on sirtuin 1 and endothelial nitric oxide synthase expression in young patients with a history of premature myocardial infarction Pubmed:29664427
JOURNAL OF LIPID RESEARCH Carotid baroreceptor stimulation in obese rats affects white and brown adipose tissues differently in metabolic protection Pubmed: 31126973
NEUROPHARMACOLOGY Caffeic acid phenethyl ester counteracts doxorubicin-induced chemobrain in Sprague-Dawley rats: Emphasis on the modulation of oxidative stress and … Pubmed: 33011510
FASEB JOURNAL Irradiation of carotid baroreceptor with low‐intensity pulsed ultrasound exerts different metabolic protection in perirenal, epididymal white adipose tissue and … Pubmed: 32954574
Exp Eye Res Autonomic nervous system receptor-mediated regulation of mast cell degranulation modulates the inflammation after corneal epithelial abrasion Pubmed:35421396
SAUDI J BIOL SCI Aqueous Ajwa dates seeds extract improves memory impairment in type-2 diabetes mellitus rats by reducing blood glucose levels and enhancing brain … Pubmed:35531250
Arq. Bras. Med. Vet. Zootec Study on the mechanisms of Suaeda rigida polysaccharides on the heart inhibition and skeletal muscle promotion in the frog
Catalog No. Related products for research use of Pan-species (General) Organism species Applications (RESEARCH USE ONLY!)
CPA912Ge11 BSA Conjugated Acetylcholine (ACH) Immunogen; SDS-PAGE; WB.
CPA912Ge21 OVA Conjugated Acetylcholine (ACH) Immunogen; SDS-PAGE; WB.
PAA912Ge01 Polyclonal Antibody to Acetylcholine (ACH) ELISA
LAA912Ge71 Biotin-Linked Polyclonal Antibody to Acetylcholine (ACH) WB; IHC; ICC.
CEA912Ge ELISA Kit for Acetylcholine (ACH) Enzyme-linked immunosorbent assay for Antigen Detection.
MEA912Ge Mini Samples ELISA Kit for Acetylcholine (ACH) Enzyme-linked immunosorbent assay for Antigen Detection.
CMA912Ge Multiplex Assay Kit for Acetylcholine (ACH) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMA912Ge Multiplex Assay Kit for Acetylcholine (ACH) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA912Ge11 ELISA Kit DIY Materials for Acetylcholine (ACH) Main materials for "Do It (ELISA Kit) Yourself".