Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for C-Peptide (CP) ,etc. by CBA (Cytometric Bead Array)
- Product No.CMA447Si
- Organism SpeciesRhesus monkey (Simian) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length3h
- Detection Range9.7656-10000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 3.2552pg/mL.
- DownloadInstruction Manual
- UOM 48T96T
- FOB
US$ 680
US$ 972
For more details, please contact local distributors!
Specificity
This assay has high sensitivity and excellent specificity for detection of C-Peptide (CP) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between C-Peptide (CP) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant C-Peptide (CP) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of C-Peptide (CP) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 80-98 | 83 |
| EDTA plasma(n=5) | 94-102 | 99 |
| heparin plasma(n=5) | 85-94 | 90 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level C-Peptide (CP) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level C-Peptide (CP) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of C-Peptide (CP) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 85-99% | 78-92% | 78-103% | 78-101% |
| EDTA plasma(n=5) | 87-95% | 96-104% | 78-96% | 80-95% |
| heparin plasma(n=5) | 95-102% | 78-95% | 88-105% | 95-104% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:CP) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
| Magazine | Citations |
| Journal of Animal Science | The effect of oral and intravenous dextrose on C-peptide secretion in ponies Pubmed:27065127 |
| Medical Science Monitor | Increased β-Cell Mass in Obese Rats after Gastric Bypass: A Potential Mechanism for Improving Glycemic Control. pubmed:28477035 |
| Journal of Alzheimers Disease | Urine-Based Biomarkers for Alzheimer's Disease Identified Through Coupling Computational and Experimental Methods Pubmed:30040720 |
| Diabetes-Metabolism Research and Reviews | Liraglutide Combined with Human Umbilical Cord Mesenchymal Stem Cell Transplantation inhibits beta‐cells apoptosis via mediating the ASK1/JNK/BAX pathway in Pubmed: 31411368 |
| Journal of dermatological treatment | Liraglutide improved inflammation via mediating IL-23/Th-17 pathway in obese diabetic mice with psoriasiform skin Pubmed: 31868553 |
| Journal of Diabetes Research | Roux-en-Y Gastric Bypass in Obese Diabetic Rats Promotes Autophagy to Improve Lipid Metabolism through mTOR/p70S6K Signaling Pathway Pubmed: 32309446 |
| Brain Research | Electroacupuncture improves cognitive deficits and insulin resistance in an OLETF rat model of Al/D-gal induced aging model via the PI3K/Akt signaling pathway Pubmed: 32304687 |
| Cancer Cell Int | Discovery and validation of FBLN1 and ANT3 as potential biomarkers for early detection of cervical cancer 33602229 |
| EUROPEAN JOURNAL OF LIPID SCIENCE AND TECHNOLOGY | Different Ratios of Corn and Coconut Oil Blends in High©\Fat Diets Influence Fat Deposition without Altering Metabolic Biomarkers in Male Rats |
| Scientific Reports | SARS-CoV2 Induced Biochemical Mechanisms in Liver Damage and Intestinal Lesions. |
| Catalog No. | Related products for research use of Rhesus monkey (Simian) Organism species | Applications (RESEARCH USE ONLY!) |
| CEA447Si | ELISA Kit for C-Peptide (CP) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| CMA447Si | Multiplex Assay Kit for C-Peptide (CP) ,etc. by CBA (Cytometric Bead Array) | FLIA Kit for Antigen Detection. |
| LMA447Si | Multiplex Assay Kit for C-Peptide (CP) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |