Multiplex Assay Kit for Platelet Derived Growth Factor AB (PDGFAB) ,etc. by CBA (Cytometric Bead Array)

PDGF-AB

Specificity

This assay has high sensitivity and excellent specificity for detection of Platelet Derived Growth Factor AB (PDGFAB) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Platelet Derived Growth Factor AB (PDGFAB) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Platelet Derived Growth Factor AB (PDGFAB) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Platelet Derived Growth Factor AB (PDGFAB) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 98-105 102
EDTA plasma(n=5) 83-99 95
heparin plasma(n=5) 78-91 87

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Platelet Derived Growth Factor AB (PDGFAB) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Platelet Derived Growth Factor AB (PDGFAB) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Platelet Derived Growth Factor AB (PDGFAB) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-101% 92-101% 82-94% 92-99%
EDTA plasma(n=5) 84-105% 78-91% 82-95% 92-101%
heparin plasma(n=5) 78-103% 87-94% 97-105% 92-102%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
PeerJ Platelet-rich concentrate in serum free medium enhances osteogenic differentiation of bone marrow-derived human mesenchymal stromal cells pubmed:27651984
Materials Science & Engineering C-Materials for Biological Applications Effect of crystalline phase changes in titania (TiO2) nanotube coatings on platelet adhesion and activation Pubmed:29025678
EXPERIMENTAL GERONTOLOGY The application of thermal oscillation method to augment the effectiveness of autologous platelet rich plasma in treating elderly patients with knee osteoarthritis Pubmed: 33091524
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
SEA436Hu ELISA Kit for Platelet Derived Growth Factor AB (PDGFAB) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA436Hu CLIA Kit for Platelet Derived Growth Factor AB (PDGFAB) Chemiluminescent immunoassay for Antigen Detection.
LMA436Hu Multiplex Assay Kit for Platelet Derived Growth Factor AB (PDGFAB) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMA436Hu Multiplex Assay Kit for Platelet Derived Growth Factor AB (PDGFAB) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.