Multiplex Assay Kit for Octamer Binding Transcription Factor 4 (OCT4) ,etc. by CBA (Cytometric Bead Array)

POU5F1; OCT3; OTF3; OTF4; Octamer-4; POU Domain Class 5 Transcription Factor 1; POU Class 5 Homoeobox 1; Octamer-binding protein 3

Specificity

This assay has high sensitivity and excellent specificity for detection of Octamer Binding Transcription Factor 4 (OCT4) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Octamer Binding Transcription Factor 4 (OCT4) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Octamer Binding Transcription Factor 4 (OCT4) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Octamer Binding Transcription Factor 4 (OCT4) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 82-102 88
EDTA plasma(n=5) 79-92 85
heparin plasma(n=5) 92-102 98

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Octamer Binding Transcription Factor 4 (OCT4) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Octamer Binding Transcription Factor 4 (OCT4) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Octamer Binding Transcription Factor 4 (OCT4) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 81-96% 81-92% 83-90% 85-96%
EDTA plasma(n=5) 78-97% 88-95% 95-102% 94-101%
heparin plasma(n=5) 94-102% 93-102% 79-93% 81-98%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Analytical Methods A universal glucometer-based biosensor for portable and quantitative detection of transcription factors Rsc: Source
Oncology Letters Upregulation of stem cell markers ALDH1A1 and OCT4 as potential biomarkers for the early detection of cervical carcinoma Doi: 10.3892/ol.2018.9381
Stem Cell Research Generation of two induced pluripotent stem cell lines NCCSi005A and NCCSi006A from CD4+ T cells of healthy individuals of Indian origin
博士论文 Experimental and Modeling Framework for the Production of Cell and Protein-Based Biopharmaceutical Products
Stem Cell Research Generation and characterization of three clones (NCCSi007A, NCCSi007B and NCCSi007C) of an integration free induced Pluripotent Stem Cell line from a … Pubmed: 31862609
J Biochem Mol Toxicol Studies on male gonadal toxicity of bisphenol A in diabetic rats: An example of exacerbation effect Pubmed:35187753