Multiplex Assay Kit for Platelet/Endothelial Cell Adhesion Molecule (PECAM1) ,etc. by CBA (Cytometric Bead Array)

CD31; EndoCAM; GPIIA'; PECA1

Specificity

This assay has high sensitivity and excellent specificity for detection of Platelet/Endothelial Cell Adhesion Molecule (PECAM1) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Platelet/Endothelial Cell Adhesion Molecule (PECAM1) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Platelet/Endothelial Cell Adhesion Molecule (PECAM1) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Platelet/Endothelial Cell Adhesion Molecule (PECAM1) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 90-98 95
EDTA plasma(n=5) 91-99 96
heparin plasma(n=5) 89-99 94

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Platelet/Endothelial Cell Adhesion Molecule (PECAM1) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Platelet/Endothelial Cell Adhesion Molecule (PECAM1) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Platelet/Endothelial Cell Adhesion Molecule (PECAM1) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 97-105% 92-105% 84-105% 94-102%
EDTA plasma(n=5) 82-89% 78-89% 90-104% 78-103%
heparin plasma(n=5) 80-89% 96-103% 80-94% 97-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
BioMed research international Endothelial gene expression and molecular changes in response to radiosurgery in in vitro and in vivo models of cerebral arteriovenous malformations Pubmed: 24199192
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA363Hu02 Recombinant Platelet/Endothelial Cell Adhesion Molecule (PECAM1) Positive Control; Immunogen; SDS-PAGE; WB.
RPA363Hu01 Recombinant Platelet/Endothelial Cell Adhesion Molecule (PECAM1) Positive Control; Immunogen; SDS-PAGE; WB.
APA363Hu61 Active Platelet/Endothelial Cell Adhesion Molecule (PECAM1) Cell culture; Activity Assays.
EPA363Hu61 Eukaryotic Platelet/Endothelial Cell Adhesion Molecule (PECAM1) Positive Control; Immunogen; SDS-PAGE; WB.
PAA363Hu01 Polyclonal Antibody to Platelet/Endothelial Cell Adhesion Molecule (PECAM1) WB; IHC; ICC/IF
PAA363Hu06 Polyclonal Antibody to Platelet/Endothelial Cell Adhesion Molecule (PECAM1) WB,IHC,ICC/IF
FAA363Hu01 Anti-Platelet/Endothelial Cell Adhesion Molecule (PECAM1) Polyclonal Antibody FCM
LAA363Hu71 Biotin-Linked Polyclonal Antibody to Platelet/Endothelial Cell Adhesion Molecule (PECAM1) WB; IHC; ICC.
MAA363Hu22 Monoclonal Antibody to Platelet/Endothelial Cell Adhesion Molecule (PECAM1) WB
MAA363Hu21 Monoclonal Antibody to Platelet/Endothelial Cell Adhesion Molecule (PECAM1) WB; ICC/IF
MAA363Hu23 Monoclonal Antibody to Platelet/Endothelial Cell Adhesion Molecule (PECAM1) WB
SEA363Hu ELISA Kit for Platelet/Endothelial Cell Adhesion Molecule (PECAM1) Enzyme-linked immunosorbent assay for Antigen Detection.
CMA363Hu Multiplex Assay Kit for Platelet/Endothelial Cell Adhesion Molecule (PECAM1) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMA363Hu Multiplex Assay Kit for Platelet/Endothelial Cell Adhesion Molecule (PECAM1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.