Multiplex Assay Kit for Caveolin 1 (CAV1) ,etc. by CBA (Cytometric Bead Array)

VIP21; Caveolae Protein 22kDa

Specificity

This assay has high sensitivity and excellent specificity for detection of Caveolin 1 (CAV1) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Caveolin 1 (CAV1) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Caveolin 1 (CAV1) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Caveolin 1 (CAV1) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 99-105 102
EDTA plasma(n=5) 96-105 101
heparin plasma(n=5) 90-104 96

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Caveolin 1 (CAV1) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Caveolin 1 (CAV1) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Caveolin 1 (CAV1) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-98% 80-95% 78-101% 78-91%
EDTA plasma(n=5) 86-105% 80-90% 91-99% 80-97%
heparin plasma(n=5) 89-104% 91-103% 80-102% 78-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Mendel Net Novel prostate cancer tumour markers in a cell line model Mendelu: source
Oncology reports Caveolin-1 as a potential high-risk prostate cancer biomarker PubMed: 22159333
Anticancer Research Increased plasma caveolin-1 levels are associated with progression of prostate cancer among Japanese men Pubmed: 23645736
Sarcoidosis Vasc Diffuse Lung Dis.? Decrased sputum caveolin-1 is associated with systemic sclerosis related lung disease Pubmed:24751454
Cancer Genomics and Proteomics Significant Association of Caveolin-1 and Caveolin-2 with Prostate Cancer Progression PubMed: 26543085
Atherosclerosis Genomic variant in CAV1 increases susceptibility to coronary artery disease and myocardial infarction Pubmed:26775120
Arthritis Research & Therapy Increased caveolin-1 in intervertebral disc degeneration facilitates repair Pubmed:26939667
Oxid Med Cell Longev Lower Serum Caveolin-1 Is Associated with Cerebral Microbleeds in Patients with Acute Ischemic Stroke Pubmed:27119011
Inflammation Caveolin-1 Promotes the Imbalance of Th17/Treg in Patients with Chronic Obstructive PulmonaryDisease. pubmed:27613621
Oxidative Medicine and Cellular Longevity Swim Training Modulates Skeletal Muscle Energy Metabolism, Oxidative Stress, and Mitochondrial Cholesterol Content in Amyotrophic Lateral Sclerosis Mice Pubmed:29849903
Microcirculation Endothelium‐dependent hyperpolarization‐mediated vasodilatation compensates nitric oxide‐mediated endothelial dysfunction during ischemia in diabetes‐induced … Pubmed:29665152
Genetic Testing and Molecular Biomarkers The CAV1 Gene 3′ Untranslated Region Single Nucleotide Polymorphisms Are Associated with the Risk of Pulmonary Hypertension in Chinese Han Chronic …
Cell Rep SIRT6 transcriptionally regulates fatty acid transport by suppressing PPAR¦Ã 34077730
researchsquare Cav-1 Protein Levels in Serum and Infarcted Brain Correlate with Hemorrhagic Volume in a Mouse Model of Thromboembolic Stroke, Independently of Rt-PA?¡­
Molecules 5, 2′-Dibromo-2, 4′, 5′-trihydroxydiphenylmethanone Inhibits LPS-Induced Vascular Inflammation by Targeting the Cav1 Protein Pubmed:35566232
Catalog No. Related products for research use of Canis familiaris; Canine (Dog) Organism species Applications (RESEARCH USE ONLY!)
RPA214Ca01 Recombinant Caveolin 1 (CAV1) Positive Control; Immunogen; SDS-PAGE; WB.
PAA214Ca01 Polyclonal Antibody to Caveolin 1 (CAV1) WB; IHC; ICC; IP.
MAA214Ca21 Monoclonal Antibody to Caveolin 1 (CAV1) WB; IHC; ICC; IP.
SEA214Ca ELISA Kit for Caveolin 1 (CAV1) Enzyme-linked immunosorbent assay for Antigen Detection.
CMA214Ca Multiplex Assay Kit for Caveolin 1 (CAV1) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMA214Ca Multiplex Assay Kit for Caveolin 1 (CAV1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.