Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Olfactomedin 4 (OLFM4) ,etc. by CBA (Cytometric Bead Array)
OLM4; hGC1; hOLfD; OlfD; GW112; GC1; G-CSF-stimulated clone 1 protein; Antiapoptotic protein GW112
- Product No.CMA162Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length4h
- Detection Range1.9531-2000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.651pg/mL.
- DownloadInstruction Manual
- UOM 48T96T
- FOB
US$ 529
US$ 756
For more details, please contact local distributors!
Specificity
This assay has high sensitivity and excellent specificity for detection of Olfactomedin 4 (OLFM4) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Olfactomedin 4 (OLFM4) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Olfactomedin 4 (OLFM4) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Olfactomedin 4 (OLFM4) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 91-99 | 94 |
| EDTA plasma(n=5) | 81-103 | 85 |
| heparin plasma(n=5) | 94-101 | 97 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Olfactomedin 4 (OLFM4) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Olfactomedin 4 (OLFM4) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Olfactomedin 4 (OLFM4) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 81-99% | 91-98% | 81-104% | 88-97% |
| EDTA plasma(n=5) | 94-105% | 79-89% | 80-89% | 93-102% |
| heparin plasma(n=5) | 78-101% | 83-96% | 90-97% | 88-104% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
| Magazine | Citations |
| Molecular & Cellular Proteomics | Integrated Proteomic Profiling of Cell Line Conditioned Media and Pancreatic Juice for the Identification of Pancreatic Cancer Biomarkers PubMed: PMC3205865 |
| PLoS One | Olfactomedin 4 serves as a marker for disease severity in pediatric respiratory syncytial virus (RSV) infection PubMed: 26162090 |
| 网页打不开 | Olfactomedin-4 serves as a prognostic marker for disease severity in pediatric respiratory syncytial virus infection 10.1.1.930.8821 |
| DSpace | Maksa rakuvälise maatriksi komponentide muutuste iseloomustamine maksakahjustuse korral handle:10062 |
| ANNALS OF TRANSLATIONAL MEDICINE | Serum levels of olfactomedin 4: a biomarker for asthma control state in asthmatics Pubmed: 32395538 |
| BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS | Notch and TNF-¦Á signaling promote cytoplasmic accumulation of OLFM4 in intestinal epithelium cells and exhibit a cell protective role in the inflamed mucosa?¡ 33490652 |
| J Inflamm Res | OLFM4 Regulates Lung Epithelial Cell Function in Sepsis-Associated ARDS/ALI via LDHA-Mediated NF-κB Signaling 34955649 |
| Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
| RPA162Hu01 | Recombinant Olfactomedin 4 (OLFM4) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAA162Hu01 | Polyclonal Antibody to Olfactomedin 4 (OLFM4) | WB |
| LAA162Hu71 | Biotin-Linked Polyclonal Antibody to Olfactomedin 4 (OLFM4) | WB; IHC; ICC. |
| MAA162Hu22 | Monoclonal Antibody to Olfactomedin 4 (OLFM4) | WB; IHC; ICC; IP. |
| SEA162Hu | ELISA Kit for Olfactomedin 4 (OLFM4) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| CMA162Hu | Multiplex Assay Kit for Olfactomedin 4 (OLFM4) ,etc. by CBA (Cytometric Bead Array) | FLIA Kit for Antigen Detection. |
| LMA162Hu | Multiplex Assay Kit for Olfactomedin 4 (OLFM4) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |