Multiplex Assay Kit for Selectin, Leukocyte (SELL) ,etc. by CBA (Cytometric Bead Array)

CD62L; L-Selectin; SEL-L; LAM1; LECAM1; LNHR; LSEL; LYAM1; Leu-8; Lyam-1; PLNHR; TQ1; HLHRc; MEL14; Lymphocyte Adhesion Molecule 1; Lymph Node Homing Receptor

Specificity

This assay has high sensitivity and excellent specificity for detection of Selectin, Leukocyte (SELL) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Selectin, Leukocyte (SELL) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Selectin, Leukocyte (SELL) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Selectin, Leukocyte (SELL) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 92-101 96
EDTA plasma(n=5) 85-97 92
heparin plasma(n=5) 96-105 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Selectin, Leukocyte (SELL) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Selectin, Leukocyte (SELL) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Selectin, Leukocyte (SELL) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 95-103% 86-98% 83-97% 84-102%
EDTA plasma(n=5) 91-101% 84-105% 83-97% 79-98%
heparin plasma(n=5) 95-105% 89-103% 81-94% 95-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Nutrition & Metabolism L-Carnitine Supplementation Increases Trimethylamine-N-Oxide but not Markers of Atherosclerosis in Healthy Aged Women Pubmed: 30485835
Cancer Management and Research iTRAQ-based quantitative protein expression profiling of biomarkers in childhood B-cell and T-cell acute lymphoblastic leukemia Pubmed: 31440093
BMC Complement Med Ther Decursinol from Angelica gigas Nakai enhances endometrial receptivity during implantation Pubmed: 32024510
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA086Hu02 Recombinant Selectin, Leukocyte (SELL) Positive Control; Immunogen; SDS-PAGE; WB.
RPA086Hu01 Recombinant Selectin, Leukocyte (SELL) Positive Control; Immunogen; SDS-PAGE; WB.
PAA086Hu01 Polyclonal Antibody to Selectin, Leukocyte (SELL) WB
MAA086Hu22 Monoclonal Antibody to Selectin, Leukocyte (SELL) WB; IHC; ICC; IP.
SEA086Hu ELISA Kit for Selectin, Leukocyte (SELL) Enzyme-linked immunosorbent assay for Antigen Detection.
CMA086Hu Multiplex Assay Kit for Selectin, Leukocyte (SELL) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMA086Hu Multiplex Assay Kit for Selectin, Leukocyte (SELL) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.