Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
ELISA Kit for Retinol (Ret)
VA; Vitamin A; Aquasola
- Product No.CED051Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample Typeserum, plasma and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length2h
- Detection Range123.5-10,000ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 45.1ng/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 571
For more details, please contact local distributors! US$ 816 US$ 3672 US$ 6936 US$ 57120
Specificity
This assay has high sensitivity and excellent specificity for detection of Retinol (Ret).
No significant cross-reactivity or interference between Retinol (Ret) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of Retinol (Ret) and the recovery rates were calculated by comparing the measured value to the expected amount of Retinol (Ret) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 80-101 | 86 |
EDTA plasma(n=5) | 87-101 | 95 |
heparin plasma(n=5) | 92-105 | 96 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Retinol (Ret) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Retinol (Ret) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Retinol (Ret) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 89-96% | 97-105% | 85-104% | 85-104% |
EDTA plasma(n=5) | 91-105% | 81-98% | 94-105% | 78-101% |
heparin plasma(n=5) | 78-101% | 81-88% | 98-105% | 81-102% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Int.J.Pharm.Med.& Biol.Sci. | Effects of Vitamin A Overdose on the Immune system in rats Jpmbs: Source |
BioMed Research International | Salivary 1, 5-Anhydroglucitol and Vitamin Levels in Relation to Caries Risk in Children |
Archives of Gynecology and Obstetrics | Oxidative stress indicators in Chinese women with PCOS and correlation with features of metabolic syndrome and dependency on lipid patterns Pubmed: 31549221 |
Prooxidant effect of α-tocopherol in pancreatic tumors. | |
Vitamin A, C, D, E and B12 Levels in Leprosy: A Case Control Study | |
BMJ Open | Protocol: Prevalence of specific micronutrient deficiencies in urban school going children of India aged between 6 and 16 years: study protocol for a … Pubmed:34907037 |
PLoS One | Prevalence of specific micronutrient deficiencies in urban school going children and adolescence of India: A multicenter cross-sectional study Pubmed:35544476 |
Clin Nutr Open Sci | Retinol Depletion in COVID-19 Pubmed:35664529 |
Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
CPD051Ge11 | BSA Conjugated Retinol (Ret) | Immunogen; SDS-PAGE; WB. |
CPD051Ge21 | OVA Conjugated Retinol (Ret) | Immunogen; SDS-PAGE; WB. |
PAD051Ge01 | Polyclonal Antibody to Retinol (Ret) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
LAD051Ge71 | Biotin-Linked Polyclonal Antibody to Retinol (Ret) | Applications: WB; IHC; ICC; IP. |
CED051Ge | ELISA Kit for Retinol (Ret) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMD051Ge | Multiplex Assay Kit for Retinol (Ret) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSD051Ge11 | ELISA Kit DIY Materials for Retinol (Ret) | Main materials for "Do It (ELISA Kit) Yourself". |