ELISA Kit for Von Willebrand Factor (vWF)
F8VWF; VWD; von Willebrand antigen 2
- Product No.CEA833Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample Typeplasma
- Test MethodCompetitive Inhibition
- Assay Length2h
- Detection Range12.35-1,000ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 5.22ng/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 441
For more details, please contact local distributors! US$ 630 US$ 2835 US$ 5355 US$ 44100
Specificity
This assay has high sensitivity and excellent specificity for detection of Von Willebrand Factor (vWF).
No significant cross-reactivity or interference between Von Willebrand Factor (vWF) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Von Willebrand Factor (vWF) and the recovery rates were calculated by comparing the measured value to the expected amount of Von Willebrand Factor (vWF) in samples.
Matrix | Recovery range (%) | Average(%) |
sodium citrate plasma(n=5) | 97-104 | 101 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Von Willebrand Factor (vWF) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Von Willebrand Factor (vWF) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Von Willebrand Factor (vWF) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
sodium citrate plasma(n=5) | 78-98% | 93-101% | 80-105% | 81-99% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1 | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
Reagent Diluent | 1×300µL | Stop Solution | 1×6mL |
TMB Substrate | 1×9mL | Instruction manual | 1 |
Wash Buffer (30 × concentrate) | 1×20mL |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Int J Nanomedicine. | Amorphous silica nanoparticles impair vascular homeostasis and induce systemic inflammation Pubmed:Pmc4047982 |
Inflammation.? | Systemic and Flap Inflammatory Response Associates with Thrombosis in Flap Venous Crisis Pubmed:25448261 |
Cellular Physiology and Biochemistry | Short-Term Nose-Only Water-Pipe (Shisha) Smoking Exposure Accelerates Coagulation and Causes Cardiac Inflammation and Oxidative Stress in Mice Pubmed:25634761 |
Asian Pac J Trop Med | Blood pH in coronary artery microthrombosis of rats PubMed: 26522304 |
Chemical Research in Toxicology | Subchronic Toxicity and Cardiovascular Responses in Spontaneously Hypertensive Rats after Exposure to Multiwalled Carbon Nanotubes by Intratracheal Instillation PubMed: 25580880 |
Sci Rep. | Differential integrative omic analysis for mechanism insights and biomarker discovery of abnormal Savda syndrome and its unique Munziq prescription Pubmed:27296761 |
American Journal of Reproductive Immunology | Circulating endothelial cells, circulating endothelial progenitor cells, and von Willebrand factor in pregnancies complicated by hypertensive disorders doi:10.1111 |
Shock | Low-Dose Sodium Nitrite Fluid Resuscitation Prevents Lethality From Crush Syndrome by Improving Nitric Oxide Consumption and Preventing Myoglobin Cytotoxicity in Kidney in A Rat Model. pubmed:27941593 |
Regenerative Biomaterials | The directional migration and differentiation of mesenchymal stem cells toward vascular endothelial cells stimulated by biphasic calcium phosphate ceramic 10.1093/rb/rbx028 |
Acta Anaesthesiologica Scandinavica | Early prognostic factors in septic shock cancer patients: a prospective study with a proteomic approach Pubmed:29315472 |
Gynecologic and obstetric investigation | Relationship between the von Willebrand Factor Plasma Concentration and Ultrasonographic Doppler Findings in Pregnancies Complicated by Hypertensive … Pubmed:29621786 |
Biological Trace Element Research | Role of Pigment Epithelium-Derived Factor in Arsenic-Induced Vascular Endothelial Dysfunction in a Rat Model Pubmed: 30392020 |
Experimental and Therapeutic Medicine | Risk stratification and prognostic evaluation of endothelial cell‑specific molecule1, von Willebrand factor, and a disintegrin‑like and metalloprotease with … |
Scientific Reports | Association between Upper-airway Surgery and Ameliorative Risk Markers of endothelial function in obstructive Sleep Apnea Pubmed: 31882827 |
International Journal of Molecular Sciences | Waterpipe Tobacco Smoke Inhalation Triggers Thrombogenicity, Cardiac Inflammation and Oxidative Stress in Mice: Effects of Flavouring Pubmed: 32075078 |
environmental research | Pigment epithelium-derived factor (PEDF) ameliorates arsenic-induced vascular endothelial dysfunction in rats and toxicity in endothelial EA. hy926 cells Pubmed: 32315827 |
evidence-based complementary and alternative medicine | Xiaoyukang Jiaonang Promotes the Degradation of Hypoxia-Inducible Factor 1α and Antiangiogenesis and Anti-Inflammation in Chronic Subdural Hematoma … Pubmed: 32228124 |
Indian Journal of Public Health Research & Development | Enhanced Fibrin-Lysis in Grade-1 Dengue Haemorrhagic Fever |
Ad hatoda Vasica: a potential ayurvedic intervention against COVID-19 associated impaired immune response and hypoxia-inflammation phenotype | |
Radiat Res | Investigating the Multi-Faceted Nature of Radiation-Induced Coagulopathies in a G?ttingen Minipig Model of Hematopoietic Acute Radiation Syndrome 34019667 |
Intensive Care Medicine Experimental | Preservation of renal endothelial integrity and reduction of renal edema by aprotinin does not preserve renal perfusion and function following experimental … 34169407 |
Experimental and Therapeutic Medicine | Salvianolic acid B improves the survival rate, acute kidney dysfunction, inflammation and NETosis‑mediated antibacterial action in a crush syndrome rat model Pubmed:35386617 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPA833Hu01 | Recombinant Von Willebrand Factor (vWF) | Positive Control; Immunogen; SDS-PAGE; WB. |
CPA833Hu21 | OVA Conjugated Von Willebrand Factor (vWF) | Immunogen; SDS-PAGE; WB. |
PAA833Hu01 | Polyclonal Antibody to Von Willebrand Factor (vWF) | WB; IHC; ICC; IP. |
PAA833Hu08 | Polyclonal Antibody to Von Willebrand Factor (vWF) | WB; IHC; ICC; IP. |
FAA833Hu01 | Anti-Von Willebrand Factor (vWF) Polyclonal Antibody | Flow cytometry. |
LAA833Hu71 | Biotin-Linked Polyclonal Antibody to Von Willebrand Factor (vWF) | WB; IHC; ICC. |
MAA833Hu22 | Monoclonal Antibody to Von Willebrand Factor (vWF) | WB; IHC; ICC; IP. |
SEA833Hu | ELISA Kit for Von Willebrand Factor (vWF) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEA833Hu | ELISA Kit for Von Willebrand Factor (vWF) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA833Hu | Multiplex Assay Kit for Von Willebrand Factor (vWF) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSA833Hu11 | ELISA Kit DIY Materials for Von Willebrand Factor (vWF) | Main materials for "Do It (ELISA Kit) Yourself". |