Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
CLIA Kit for Glycated Hemoglobin A1c (HbA1c)
Glycosylated Hemoglobin; Hemoglobin A1c; Hb1c; HbAIc; HbAIc
- Product No.CCA190Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample Typeserum, plasma and erythrocyte lysates
- Test MethodCompetitive Inhibition
- Assay Length2h
- Detection Range5.86-1,500μg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 2.44μg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 529
For more details, please contact local distributors! US$ 756 US$ 3402 US$ 6426 US$ 52920
Specificity
This assay has high sensitivity and excellent specificity for detection of Glycated Hemoglobin A1c (HbA1c).
No significant cross-reactivity or interference between Glycated Hemoglobin A1c (HbA1c) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Glycated Hemoglobin A1c (HbA1c) and the recovery rates were calculated by comparing the measured value to the expected amount of Glycated Hemoglobin A1c (HbA1c) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 78-93 | 81 |
EDTA plasma(n=5) | 83-93 | 88 |
heparin plasma(n=5) | 83-91 | 88 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glycated Hemoglobin A1c (HbA1c) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glycated Hemoglobin A1c (HbA1c) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glycated Hemoglobin A1c (HbA1c) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 78-91% | 85-93% | 88-102% | 81-103% |
EDTA plasma(n=5) | 82-94% | 78-101% | 84-97% | 79-99% |
heparin plasma(n=5) | 80-90% | 82-93% | 91-105% | 78-96% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
Substrate A | 1×10mL | Substrate B | 1×2mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
7. Read RLU value immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
J Am Coll Nutr | The Effect of Vitamin D Supplementation on Glycemic Control and Lipid Profile in Patients with Type 2 Diabetes Mellitus PubMed: 26391639 |
Journal of the American College of Nutrition | The Effect of Vitamin D Supplementation on Glycemic Control and Lipid Profile in Patients with Type 2 Diabetes Mellitus. pubmed:26391639 |
Journal of Endocrinology and Metabolism | Circulating Betatrophin and Hepatocyte Growth Factor in Type 2 Diabetic Patients: Their Relationship With Disease Prognosis 405 |
Molecular nutrition & food research | Chicory inulin ameliorates type 2 diabetes mellitus and suppresses JNK and MAPK pathways in vivo and in vitro pubmed:28105758 |
33 | d-Ribose as a Contributor to Glycated Haemoglobin pubmed:29033370 |
Journal of Functional Foods | Hypoglycemic effect of Hypericum attenuatum Choisy extracts on type 2 diabetes by regulating glucolipid metabolism and modulating gut microbiota |
West Indian Medical Journal | Plasma Cellular Hypoxia, Mitochondrial Dysfunction, Disease Risk and Prognostic Factors in Type 2 Diabetic Patients in Saudi Arabia. |
Journal of Occupational and Environmental Hygiene | Stressors, allostatic load, and health outcomes among women hotel housekeepers: A pilot study Pubmed: 30615593 |
Cell Reports | Parabacteroides distasonis Alleviates Obesity and Metabolic Dysfunctions via Production of Succinate and Secondary Bile Acids Pubmed: 30605678 |
Journal of Agricultural and Food Chemistry | Gymnemic acid alleviates type 2 diabetes mellitus and suppresses endoplasmic reticulum stress in vivo and in vitro |
Journal of Clinical Medicine | 1H Nuclear Magnetic Resonance (NMR)-Based Cerebrospinal Fluid and Plasma Metabolomic Analysis in Type 2 Diabetic Patients and Risk Prediction for Diabetic … Pubmed: 31248127 |
Food & Function | Gymnemic Acid Alleviates Inflammation and Insulin Resistance via PPARδ-and NFκB-mediated pathways in db/db mice. |
Obesity Surgery | Duodenal-Jejunal Bypass Ameliorates Type 2 Diabetes Mellitus by Activating Insulin Signaling and Improving Glucose Utilization in the Brain Pubmed: 31605365 |
Acta Diabetologica | Modulation of gut microbiota contributes to effects of intensive insulin therapy on intestinal morphological alteration in high-fat-diet-treated mice Pubmed: 31749050 |
Open Access Macedonian Journal of Medical Sciences | Inhibition of Receptor for Advanced Glycation End Products as New Promising Strategy Treatment in Diabetic Retinopathy Pubmed: 32165929 |
Cell Reports | Activation of a Specific Gut Bacteroides-Folate-Liver Axis Benefits for the Alleviation of Nonalcoholic Hepatic Steatosis Pubmed: 32783933 |
The effects of different intensity endurance and resistance exercise on diabetic-related blood profiles in impaired glucose tolerance mice | |
Revista Internacional de Andrologia | Relation of pharmacopenile duplex ultrasonography parameters and glycated hemoglobin (HbA1c) in diabetic patients with erectile dysfunction 33334711 |
Advanced Theory and Simulations? | Identification of Key Contributive Compounds in a Herbal Medicine: A Novel Mathematic¡ªBiological Evaluation Approach |
Dis Markers | The Roles of Liver Inflammation and the Insulin Signaling Pathway in PM2. 5 Instillation-Induced Insulin Resistance in Wistar Rats 34745386 |
Antioxidants | Antioxidant Effect of Tyr-Ala Extracted from Zein on INS-1 Cells and Type 2 Diabetes High-Fat-Diet-Induced Mice Pubmed:35740008 |
P001–Inv. Clínica |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
NPA190Hu01 | Native Glycated Hemoglobin A1c (HbA1c) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA190Hu01 | Polyclonal Antibody to Glycated Hemoglobin A1c (HbA1c) | WB; IHC; ICC; IP. |
LAA190Hu71 | Biotin-Linked Polyclonal Antibody to Glycated Hemoglobin A1c (HbA1c) | WB; IHC; ICC. |
MAA190Hu21 | Monoclonal Antibody to Glycated Hemoglobin A1c (HbA1c) | WB; IHC; ICC; IP. |
MAA190Hu22 | Monoclonal Antibody to Glycated Hemoglobin A1c (HbA1c) | WB; IHC; ICC; IP. |
CEA190Hu | ELISA Kit for Glycated Hemoglobin A1c (HbA1c) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CCA190Hu | CLIA Kit for Glycated Hemoglobin A1c (HbA1c) | Chemiluminescent immunoassay for Antigen Detection. |
LMA190Hu | Multiplex Assay Kit for Glycated Hemoglobin A1c (HbA1c) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSA190Hu01 | ELISA Kit DIY Materials for Glycated Hemoglobin A1c (HbA1c) | Main materials for "Do It (ELISA Kit) Yourself". |
KSA190Hu11 | ELISA Kit DIY Materials for Glycated Hemoglobin A1c (HbA1c) | Main materials for "Do It (ELISA Kit) Yourself". |