ELISA Kit for Organic Cation/Ergothioneine Transporter (OCTN1)

SLC22A4; ETT; UT2H; Solute Carrier Family 22 Member 4; ET transporter

Specificity

This assay has high sensitivity and excellent specificity for detection of Organic Cation/Ergothioneine Transporter (OCTN1).
No significant cross-reactivity or interference between Organic Cation/Ergothioneine Transporter (OCTN1) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Organic Cation/Ergothioneine Transporter (OCTN1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Organic Cation/Ergothioneine Transporter (OCTN1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Biochemical and biophysical research communications Ergothioneine levels in an elderly population decrease with age and incidence of cognitive decline; a risk factor for neurodegeneration? pubmed:27444382
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPE444Hu01 Recombinant Organic Cation/Ergothioneine Transporter (OCTN1) Positive Control; Immunogen; SDS-PAGE; WB.
PAE444Hu01 Polyclonal Antibody to Organic Cation/Ergothioneine Transporter (OCTN1) WB
MAE444Hu21 Monoclonal Antibody to Organic Cation/Ergothioneine Transporter (OCTN1) WB
MAE444Hu22 Monoclonal Antibody to Organic Cation/Ergothioneine Transporter (OCTN1) WB; IHC; ICC; IP.
MAE444Hu23 Monoclonal Antibody to Organic Cation/Ergothioneine Transporter (OCTN1) WB; IHC; ICC; IP.
SEE444Hu ELISA Kit for Organic Cation/Ergothioneine Transporter (OCTN1) Enzyme-linked immunosorbent assay for Antigen Detection.
LME444Hu Multiplex Assay Kit for Organic Cation/Ergothioneine Transporter (OCTN1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.