ELISA Kit for Bactericidal/Permeability Increasing Protein (BPI)

CAP 57

Specificity

This assay has high sensitivity and excellent specificity for detection of Bactericidal/Permeability Increasing Protein (BPI).
No significant cross-reactivity or interference between Bactericidal/Permeability Increasing Protein (BPI) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Bactericidal/Permeability Increasing Protein (BPI) and the recovery rates were calculated by comparing the measured value to the expected amount of Bactericidal/Permeability Increasing Protein (BPI) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 93-101 96
EDTA plasma(n=5) 93-105 97
heparin plasma(n=5) 83-97 87

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Bactericidal/Permeability Increasing Protein (BPI) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Bactericidal/Permeability Increasing Protein (BPI) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Bactericidal/Permeability Increasing Protein (BPI) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-92% 84-93% 94-103% 78-105%
EDTA plasma(n=5) 92-99% 89-103% 78-104% 82-101%
heparin plasma(n=5) 92-105% 81-90% 92-101% 93-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
The Journal of International Medical Research Effects of Acute Hypervolaemic Haemodilution on the Expression of Plasma Interferon-inducible Protein-10 and Bactericidal/Permeability-increasing Protein in Patients Undergoing Total Hip Replacement Ingenta: art00020
AIDS Oral serum-derived bovine immunoglobulin improves duodenal immune reconstitution and absorption function in patients with HIV enteropathy PubMed: PMC3754419
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPB234Mu01 Recombinant Bactericidal/Permeability Increasing Protein (BPI) Positive Control; Immunogen; SDS-PAGE; WB.
RPB234Mu02 Recombinant Bactericidal/Permeability Increasing Protein (BPI) Positive Control; Immunogen; SDS-PAGE; WB.
PAB234Mu02 Polyclonal Antibody to Bactericidal/Permeability Increasing Protein (BPI) WB; IHC; ICC; IP.
PAB234Mu01 Polyclonal Antibody to Bactericidal/Permeability Increasing Protein (BPI) WB; IHC; ICC; IP.
SEB234Mu ELISA Kit for Bactericidal/Permeability Increasing Protein (BPI) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB234Mu Multiplex Assay Kit for Bactericidal/Permeability Increasing Protein (BPI) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.