Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
ELISA Kit for Interleukin 15 (IL15)
- Product No.SEA061Bo
- Organism SpeciesBos taurus; Bovine (Cattle) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range15.6-1,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 5.7pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 529
For more details, please contact local distributors! US$ 756 US$ 3402 US$ 6426 US$ 52920
Specificity
This assay has high sensitivity and excellent specificity for detection of Interleukin 15 (IL15).
No significant cross-reactivity or interference between Interleukin 15 (IL15) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Interleukin 15 (IL15) and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 15 (IL15) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 82-97 | 89 |
EDTA plasma(n=5) | 91-101 | 97 |
heparin plasma(n=5) | 85-98 | 90 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 15 (IL15) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 15 (IL15) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 15 (IL15) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 95-105% | 84-99% | 91-98% | 96-105% |
EDTA plasma(n=5) | 83-104% | 79-90% | 88-101% | 99-105% |
heparin plasma(n=5) | 98-105% | 92-105% | 97-105% | 93-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
- Single-component Reagents of Assay Kit
- Lysis Buffer Specific for ELISA / CLIA
- Quality Control of Kit
- ELISA Kit Customized Service
- Disease Model Customized Service
- Serums Customized Service
- TGFB1 Activation Reagent
- Real Time PCR Experimental Service
- Streptavidin
- Fast blue Protein Stain solution
- Single-component Reagents of FLIA Kit
- Streptavidin-Agarose Beads
Magazine | Citations |
Endocrine | Expression of interleukin-15 and inflammatory cytokines in skeletal muscles of STZ-induced diabetic rats: effect of resistance exercise training Pubmed: 24006180 |
Endocrine | Time course of IL-15 expression after acute resistance exercise in trained rats: effect of diabetes and skeletal muscle phenotype Pubmed:25522723 |
Med Sci Moni | miR-15b is Downregulated in Myasthenia Gravis Patients and Directly Regulates the Expression of Interleukin-15 (IL-15) in Experimental Myasthenia Gravis Mice PubMed: 26087886 |
Exercise physiology | Effects of intrinsic aerobic capacity, aging and physical activity on interleukin-15 protein level in serum and skeletal muscle Dspace: Handle |
Biotechnology Letters | Novel adjuvant for immunization against tuberculosis: DNA vaccine expressing Mycobacterium tuberculosis antigen 85A and interleukin-15 fusion product elicits strong immune responses in mice s10529-017-2342-1 |
Journal of Controlled Release | Interleukin-15 and cisplatin co-encapsulated thermosensitive polypeptide hydrogels for combined immuno-chemotherapy. pubmed:28408199 |
Catalog No. | Related products for research use of Bos taurus; Bovine (Cattle) Organism species | Applications (RESEARCH USE ONLY!) |
RPA061Bo01 | Recombinant Interleukin 15 (IL15) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA061Bo01 | Polyclonal Antibody to Interleukin 15 (IL15) | WB; IHC; ICC; IP. |
LAA061Bo81 | FITC-Linked Polyclonal Antibody to Interleukin 15 (IL15) | WB; IHC; ICC; IF. |
MAA061Bo21 | Monoclonal Antibody to Interleukin 15 (IL15) | WB; IHC; ICC; IP. |
SEA061Bo | ELISA Kit for Interleukin 15 (IL15) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA061Bo | Multiplex Assay Kit for Interleukin 15 (IL15) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |