Multiplex Assay Kit for Insulin Like Protein 3 (INSL3) ,etc. by FLIA (Flow Luminescence Immunoassay)

RLNL; RLF; Relaxin-Like Factor,Leydig Cell; Leydig insulin-like peptide

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Insulin Like Protein 3 (INSL3) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Insulin Like Protein 3 (INSL3) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Insulin Like Protein 3 (INSL3) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Insulin Like Protein 3 (INSL3) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 98-105 102
EDTA plasma(n=5) 87-101 91
heparin plasma(n=5) 79-88 82

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Insulin Like Protein 3 (INSL3) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Insulin Like Protein 3 (INSL3) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Insulin Like Protein 3 (INSL3) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-98% 93-103% 98-105% 98-105%
EDTA plasma(n=5) 92-104% 94-101% 89-102% 92-104%
heparin plasma(n=5) 84-98% 87-101% 78-90% 95-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:INSL3) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Adv Med Sci. Are anti-MĂźllerian hormone and its receptor polymorphism associated with the hormonal condition of undescended testes? Pubmed:27162065
Journal of Clinical Research in Pediatric Endocrinology Anti-Müllerian Hormone and Inhibin-A, but not Inhibin-B or Insulin-Like Peptide-3, may be Used as Surrogates in the Diagnosis of Polycystic Ovary Syndrome in Adolescents: Preliminary Results. pubmed:27125339
Bioscience, Biotechnology, and Biochemistry Salivary lactoferrin is transferred into the brain via the sublingual route pubmed:28351211
Seed canals. Leydig and Sertoli cells function in patients with genital ambiguity
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPD873Hu01 Recombinant Insulin Like Protein 3 (INSL3) Positive Control; Immunogen; SDS-PAGE; WB.
PAD873Hu01 Polyclonal Antibody to Insulin Like Protein 3 (INSL3) WB; IHC; ICC; IP.
MAD873Hu21 Monoclonal Antibody to Insulin Like Protein 3 (INSL3) WB; IHC; ICC; IP.
SED873Hu ELISA Kit for Insulin Like Protein 3 (INSL3) Enzyme-linked immunosorbent assay for Antigen Detection.