Multiplex Assay Kit for Homing Associated Cell Adhesion Molecule (HCAM) ,etc. by FLIA (Flow Luminescence Immunoassay)

CDW44; CD44; CSPG8; ECMR-III; HCELL; IN; LHR; MC56; MDU2; MDU3; MIC4; MUTCH-I; Pgp1; Hematopoietic Cell E- And L-Selectin Ligand; Chondroitin Sulfate Proteoglycan 8

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Homing Associated Cell Adhesion Molecule (HCAM) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Homing Associated Cell Adhesion Molecule (HCAM) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Homing Associated Cell Adhesion Molecule (HCAM) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Homing Associated Cell Adhesion Molecule (HCAM) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-90 85
EDTA plasma(n=5) 82-96 88
heparin plasma(n=5) 92-102 96
sodium citrate plasma(n=5) 91-101 96

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Homing Associated Cell Adhesion Molecule (HCAM) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Homing Associated Cell Adhesion Molecule (HCAM) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Homing Associated Cell Adhesion Molecule (HCAM) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 84-98% 90-101% 93-101% 90-101%
EDTA plasma(n=5) 83-101% 97-105% 84-102% 84-96%
heparin plasma(n=5) 93-105% 85-93% 84-98% 85-103%
sodium citrate plasma(n=5) 87-102% 88-99% 86-95% 84-99%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:HCAM) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Cancers Predictive Value of Soluble PD-1, PD-L1, VEGFA, CD40 Ligand and CD44 for Nivolumab Therapy in Advanced Non-Small Cell Lung Cancer: A Case-Control Study Pubmed: 32085544
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA670Hu01 Recombinant Homing Associated Cell Adhesion Molecule (HCAM) Positive Control; Immunogen; SDS-PAGE; WB.
EPA670Hu61 Eukaryotic Homing Associated Cell Adhesion Molecule (HCAM) Positive Control; Immunogen; SDS-PAGE; WB.
EPA670Hu62 Eukaryotic Homing Associated Cell Adhesion Molecule (HCAM) Positive Control; Immunogen; SDS-PAGE; WB.
APA670Hu61 Active Homing Associated Cell Adhesion Molecule (HCAM) Cell culture; Activity Assays.
CPA670Hu21 OVA Conjugated Homing Associated Cell Adhesion Molecule (HCAM) Immunogen; SDS-PAGE; WB.
PAA670Hu01 Polyclonal Antibody to Homing Associated Cell Adhesion Molecule (HCAM) WB; IHC; ICC; IP.
PAA670Hu08 Polyclonal Antibody to Homing Associated Cell Adhesion Molecule (HCAM) WB; IHC; ICC; IP.
LAA670Hu61 Cy3-Linked Polyclonal Antibody to Homing Associated Cell Adhesion Molecule (HCAM) WB; IHC; ICC; IF.
MAA670Hu21 Monoclonal Antibody to Homing Associated Cell Adhesion Molecule (HCAM) WB; IHC; ICC; IP.
MAA670Hu22 Monoclonal Antibody to Homing Associated Cell Adhesion Molecule (HCAM) WB; IHC; ICC; IP.
MAA670Hu23 Monoclonal Antibody to Homing Associated Cell Adhesion Molecule (HCAM) WB; IHC; ICC; IP.
MAA670Hu24 Monoclonal Antibody to Homing Associated Cell Adhesion Molecule (HCAM) WB; IHC; ICC; IP.
MAA670Hu27 Monoclonal Antibody to Homing Associated Cell Adhesion Molecule (HCAM) WB; IHC; ICC; IP.
MAA670Hu29 Monoclonal Antibody to Homing Associated Cell Adhesion Molecule (HCAM) WB; IHC; ICC; IP.
MAA670Hu25 Monoclonal Antibody to Homing Associated Cell Adhesion Molecule (HCAM) WB; IHC; ICC; IP.
MAA670Hu26 Monoclonal Antibody to Homing Associated Cell Adhesion Molecule (HCAM) WB; IHC; ICC; IP.
FAA670Hu02 Anti-Homing Associated Cell Adhesion Molecule (HCAM) Monoclonal Antibody FCM
FAA670Hu04 Anti-Homing Associated Cell Adhesion Molecule (HCAM) Monoclonal Antibody FCM
FAA670Hu06 Anti-Homing Associated Cell Adhesion Molecule (HCAM) Monoclonal Antibody FCM
FAA670Hu08 Anti-Homing Associated Cell Adhesion Molecule (HCAM) Monoclonal Antibody FCM
SEA670Hu ELISA Kit for Homing Associated Cell Adhesion Molecule (HCAM) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA670Hu Multiplex Assay Kit for Homing Associated Cell Adhesion Molecule (HCAM) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.