ELISA Kit for G Protein Coupled Receptor 35 (GPR35)

KYNA receptor; Kynurenic acid receptor

Specificity

This assay has high sensitivity and excellent specificity for detection of G Protein Coupled Receptor 35 (GPR35).
No significant cross-reactivity or interference between G Protein Coupled Receptor 35 (GPR35) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level G Protein Coupled Receptor 35 (GPR35) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level G Protein Coupled Receptor 35 (GPR35) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPG725Hu01 Recombinant G Protein Coupled Receptor 35 (GPR35) Positive Control; Immunogen; SDS-PAGE; WB.
PAG725Hu01 Polyclonal Antibody to G Protein Coupled Receptor 35 (GPR35) WB; IHC; ICC; IP.
MAG725Hu21 Monoclonal Antibody to G Protein Coupled Receptor 35 (GPR35) WB
SEG725Hu ELISA Kit for G Protein Coupled Receptor 35 (GPR35) Enzyme-linked immunosorbent assay for Antigen Detection.
LMG725Hu Multiplex Assay Kit for G Protein Coupled Receptor 35 (GPR35) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.