CLIA Kit for Defensin Alpha 1, Neutrophil (DEFa1)

DEF1; DEFA2; HNP-1; HP-1; MRS; DEF3; HNP-3; HNP3; HP-3; Defensin,Alpha 1; Myeloid-Related Sequence

Specificity

This assay has high sensitivity and excellent specificity for detection of Defensin Alpha 1, Neutrophil (DEFa1).
No significant cross-reactivity or interference between Defensin Alpha 1, Neutrophil (DEFa1) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Defensin Alpha 1, Neutrophil (DEFa1) and the recovery rates were calculated by comparing the measured value to the expected amount of Defensin Alpha 1, Neutrophil (DEFa1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 92-99 96
EDTA plasma(n=5) 93-101 97
heparin plasma(n=5) 79-97 85

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Defensin Alpha 1, Neutrophil (DEFa1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Defensin Alpha 1, Neutrophil (DEFa1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Defensin Alpha 1, Neutrophil (DEFa1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 78-103% 95-104% 91-98%
EDTA plasma(n=5) 89-101% 78-95% 93-105% 91-98%
heparin plasma(n=5) 80-93% 79-99% 88-102% 92-99%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
Substrate A 1×10mL Substrate B 1×2mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
PLoS One. Cerebrospinal Fluid Biomarker Candidates Associated with Human WNV Neuroinvasive Disease Plos: Source
The prognosis and investigation of a-defensin-1 (hnp-1) influence on morphological changes of Staphylococcus aureus cells by the atomic-force microscopy data 10.14300/mnnc.2017.12086 ISSN - 2073-8137
Scientific Reports Leukotriene B4 is essential for lung host defence and alpha-defensin-1 production during Achromobacter xylosoxidans infection. pubmed:29247243
Comparison of human and mouse fetal intestinal tissues reveals differential maturation timelines.
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB705Hu01 Recombinant Defensin Alpha 1, Neutrophil (DEFa1) Positive Control; Immunogen; SDS-PAGE; WB.
PAB705Hu01 Polyclonal Antibody to Defensin Alpha 1, Neutrophil (DEFa1) WB; ICC; IHC-P; IHC-F; ELISA.
MAB705Hu22 Monoclonal Antibody to Defensin Alpha 1, Neutrophil (DEFa1) WB; IHC; ICC; IP.
SEB705Hu ELISA Kit for Defensin Alpha 1, Neutrophil (DEFa1) Enzyme-linked immunosorbent assay for Antigen Detection.
SCB705Hu CLIA Kit for Defensin Alpha 1, Neutrophil (DEFa1) Chemiluminescent immunoassay for Antigen Detection.
LMB705Hu Multiplex Assay Kit for Defensin Alpha 1, Neutrophil (DEFa1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSB705Hu01 ELISA Kit DIY Materials for Defensin Alpha 1, Neutrophil (DEFa1) Main materials for "Do It (ELISA Kit) Yourself".