Multiplex Assay Kit for C-Peptide (CP) ,etc. by FLIA (Flow Luminescence Immunoassay)

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of C-Peptide (CP) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between C-Peptide (CP) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant C-Peptide (CP) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of C-Peptide (CP) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-92 85
EDTA plasma(n=5) 94-101 98
heparin plasma(n=5) 98-105 102
sodium citrate plasma(n=5) 79-93 84

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level C-Peptide (CP) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level C-Peptide (CP) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of C-Peptide (CP) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-89% 97-105% 94-102% 94-101%
EDTA plasma(n=5) 79-94% 96-104% 82-93% 96-103%
heparin plasma(n=5) 85-104% 78-104% 78-102% 92-103%
sodium citrate plasma(n=5) 88-96% 78-97% 79-91% 86-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:CP) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Journal of Animal Science The effect of oral and intravenous dextrose on C-peptide secretion in ponies Pubmed:27065127
Medical Science Monitor Increased β-Cell Mass in Obese Rats after Gastric Bypass: A Potential Mechanism for Improving Glycemic Control. pubmed:28477035
Journal of Alzheimers Disease Urine-Based Biomarkers for Alzheimer's Disease Identified Through Coupling Computational and Experimental Methods Pubmed:30040720
Diabetes-Metabolism Research and Reviews Liraglutide Combined with Human Umbilical Cord Mesenchymal Stem Cell Transplantation inhibits beta‐cells apoptosis via mediating the ASK1/JNK/BAX pathway in Pubmed: 31411368
Journal of dermatological treatment Liraglutide improved inflammation via mediating IL-23/Th-17 pathway in obese diabetic mice with psoriasiform skin Pubmed: 31868553
Journal of Diabetes Research Roux-en-Y Gastric Bypass in Obese Diabetic Rats Promotes Autophagy to Improve Lipid Metabolism through mTOR/p70S6K Signaling Pathway Pubmed: 32309446
Brain Research Electroacupuncture improves cognitive deficits and insulin resistance in an OLETF rat model of Al/D-gal induced aging model via the PI3K/Akt signaling pathway Pubmed: 32304687
Cancer Cell Int Discovery and validation of FBLN1 and ANT3 as potential biomarkers for early detection of cervical cancer 33602229
EUROPEAN JOURNAL OF LIPID SCIENCE AND TECHNOLOGY Different Ratios of Corn and Coconut Oil Blends in High©\Fat Diets Influence Fat Deposition without Altering Metabolic Biomarkers in Male Rats
Scientific Reports SARS-CoV2 Induced Biochemical Mechanisms in Liver Damage and Intestinal Lesions.
Catalog No. Related products for research use of Rhesus monkey (Simian) Organism species Applications (RESEARCH USE ONLY!)
CEA447Si ELISA Kit for C-Peptide (CP) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA447Si Multiplex Assay Kit for C-Peptide (CP) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.