ELISA Kit for Hemoglobin (HB)

Hgb; Haemoglobin; Heterotetramer(αβ)2

Specificity

This assay has high sensitivity and excellent specificity for detection of Hemoglobin (HB).
No significant cross-reactivity or interference between Hemoglobin (HB) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Hemoglobin (HB) and the recovery rates were calculated by comparing the measured value to the expected amount of Hemoglobin (HB) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 91-99 94
EDTA plasma(n=5) 79-88 83

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Hemoglobin (HB) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Hemoglobin (HB) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Hemoglobin (HB) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 96-103% 86-98% 90-98%
EDTA plasma(n=5) 96-105% 96-105% 87-94% 97-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Comparative Biochemistry and Physiology Part C: Toxicology &amp; Pharmacology Effects of ectoine on behavioural, physiological and biochemical parameters of Daphnia magna Pubmed:25460046
PLoS One. Comparative Proteomics Identifies Host Immune System Proteins Affected by Infection with Mycobacterium bovis Pubmed:27027307
Parasites & Vectors The intracellular bacterium Anaplasma phagocytophilum selectively manipulates the levels of vertebrate host proteins in the tick vector Ixodes scapularis. pubmed:27561965
Proteomics. Clinical Applications Elevated levels of protein AMBP in cerebrospinal fluid of women with preeclampsia compared to normotensive pregnant women. pubmed:27615121
Molecular nutrition & food research Chicory inulin ameliorates type 2 diabetes mellitus and suppresses JNK and MAPK pathways in vivo and in vitro pubmed:28105758
Frontiers in Immunology Oxidized Hemoglobin Is Antigenic and Immunogenic in Lupus pubmed:28694810
新規人工酸素運搬体HemoAct を用いた脳虚血再灌流障害治療開発に関する研究 :
Acta Neuropathologica Communications Mural cell-derived laminin-α5 plays a detrimental role in ischemic stroke Pubmed: 30777135
Angiogenesis Decylubiquinone suppresses breast cancer growth and metastasis by inhibiting angiogenesis via the ROS/p53/BAI1 signaling pathway Pubmed: 32020421
Food Bioscience Water-extractable zinc protoporphyrin IX in Parma ham predominantly exists as complexes with hemoglobin and myoglobin
Photochem Photobiol Effects of Human Serum Albumin on the Fluorescence Intensity and Tumor Imaging Properties of IR‐780 Dye 34687567
Catalog No. Related products for research use of Ovis aries; Ovine (Sheep) Organism species Applications (RESEARCH USE ONLY!)
CEB409Ov ELISA Kit for Hemoglobin (HB) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB409Ov Multiplex Assay Kit for Hemoglobin (HB) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.